CPR induced inappropriate shocks from a subcutaneous implantable cardioverter defibrillator during out-of-hospital cardiac arrest
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216208%3A11120%2F20%3A43917896" target="_blank" >RIV/00216208:11120/20:43917896 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/44555601:13450/19:43894899
Výsledek na webu
<a href="https://doi.org/10.1080/10903127.2019.1599475" target="_blank" >https://doi.org/10.1080/10903127.2019.1599475</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1080/10903127.2019.1599475" target="_blank" >10.1080/10903127.2019.1599475</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
CPR induced inappropriate shocks from a subcutaneous implantable cardioverter defibrillator during out-of-hospital cardiac arrest
Popis výsledku v původním jazyce
We present the case of a 30-year-old man with a subcutaneous implantable cardioverter defibrillator (S-ICD) who suffered sudden out-of-hospital cardiac arrest. During resuscitation, the patient received inappropriate shocks due to oversensing by the S-ICD of chest compression induced artifact. The rhythm on the EMS monitor showed asystole throughout the period of resuscitation. Placement of a magnet over the S-ICD generator failed to inhibit the delivery of S-ICD shocks. Information regarding inappropriate S-ICD shocks may be useful during resuscitation of patients with sudden cardiac arrest.
Název v anglickém jazyce
CPR induced inappropriate shocks from a subcutaneous implantable cardioverter defibrillator during out-of-hospital cardiac arrest
Popis výsledku anglicky
We present the case of a 30-year-old man with a subcutaneous implantable cardioverter defibrillator (S-ICD) who suffered sudden out-of-hospital cardiac arrest. During resuscitation, the patient received inappropriate shocks due to oversensing by the S-ICD of chest compression induced artifact. The rhythm on the EMS monitor showed asystole throughout the period of resuscitation. Placement of a magnet over the S-ICD generator failed to inhibit the delivery of S-ICD shocks. Information regarding inappropriate S-ICD shocks may be useful during resuscitation of patients with sudden cardiac arrest.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
30221 - Critical care medicine and Emergency medicine
Návaznosti výsledku
Projekt
—
Návaznosti
V - Vyzkumna aktivita podporovana z jinych verejnych zdroju
Ostatní
Rok uplatnění
2020
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Prehospital Emergency Care
ISSN
1090-3127
e-ISSN
—
Svazek periodika
24
Číslo periodika v rámci svazku
1
Stát vydavatele periodika
US - Spojené státy americké
Počet stran výsledku
5
Strana od-do
85-89
Kód UT WoS článku
000466029500001
EID výsledku v databázi Scopus
2-s2.0-85064545346