Morphology of the vasculature and blood supply of the brown adipose tissue examined in an animal model by micro-CT
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216208%3A11120%2F20%3A43919749" target="_blank" >RIV/00216208:11120/20:43919749 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/68407700:21460/20:00346504 RIV/68407700:21670/20:00346504
Výsledek na webu
<a href="https://doi.org/10.1155/2020/7502578" target="_blank" >https://doi.org/10.1155/2020/7502578</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1155/2020/7502578" target="_blank" >10.1155/2020/7502578</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Morphology of the vasculature and blood supply of the brown adipose tissue examined in an animal model by micro-CT
Popis výsledku v původním jazyce
We performed micro-CT imaging of the vascular blood supply in the interscapular area of the brown adipose tissue in three mice with the use of intravascular contrast agent AurovistTM. Resulting 3D data rendering was then adapted into 2D resolution with visualization using false colors system and grayscale images. These were then studied for the automatic quantification of the blood vessel density within this area. We found the highest most occuring density within arterioles or venules representing smaller blood vessels whereas with the increase of the vessels diameters a lower percentage rate of their presence was observed in the sample. Our study shows that micro-CT scanning in combination with AurovistTM contrast is suitable for anatomical studies of interscapular area brown adipose tissue blood vessel supply.
Název v anglickém jazyce
Morphology of the vasculature and blood supply of the brown adipose tissue examined in an animal model by micro-CT
Popis výsledku anglicky
We performed micro-CT imaging of the vascular blood supply in the interscapular area of the brown adipose tissue in three mice with the use of intravascular contrast agent AurovistTM. Resulting 3D data rendering was then adapted into 2D resolution with visualization using false colors system and grayscale images. These were then studied for the automatic quantification of the blood vessel density within this area. We found the highest most occuring density within arterioles or venules representing smaller blood vessels whereas with the increase of the vessels diameters a lower percentage rate of their presence was observed in the sample. Our study shows that micro-CT scanning in combination with AurovistTM contrast is suitable for anatomical studies of interscapular area brown adipose tissue blood vessel supply.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
30106 - Anatomy and morphology (plant science to be 1.6)
Návaznosti výsledku
Projekt
<a href="/cs/project/EF16_019%2F0000766" target="_blank" >EF16_019/0000766: Inženýrské aplikace fyziky mikrosvěta</a><br>
Návaznosti
S - Specificky vyzkum na vysokych skolach<br>I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2020
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
BioMed Research International
ISSN
2314-6133
e-ISSN
—
Svazek periodika
2020
Číslo periodika v rámci svazku
February
Stát vydavatele periodika
US - Spojené státy americké
Počet stran výsledku
6
Strana od-do
"Article 7502578"
Kód UT WoS článku
000522122300009
EID výsledku v databázi Scopus
2-s2.0-85082012008