Pacing-induced right ventricular cardiomyopathy resynchronized using His bundle pacing
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216208%3A11120%2F20%3A43920003" target="_blank" >RIV/00216208:11120/20:43920003 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/00064173:_____/20:N0000105
Výsledek na webu
<a href="https://doi.org/10.33678/cor.2019.011" target="_blank" >https://doi.org/10.33678/cor.2019.011</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.33678/cor.2019.011" target="_blank" >10.33678/cor.2019.011</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Pacing-induced right ventricular cardiomyopathy resynchronized using His bundle pacing
Popis výsledku v původním jazyce
Permanent unifocal right ventricular pacing can lead to ventricular dyssynchrony with subsequent dysfunction of the left ventricle, which can lead to heart failure. Heart failure caused by right ventricular pacing was traditionally associated with pacing from the apex of the right ventricle. Over the last two decades, significant efforts have been made to find alternative pacing sites that can reduce or prevent the risk of heart failure. Based on the latest findings, pacing the His bundle area appears extremely promising. In this case report, we present a 79-year-old male, who developed left ventricular dysfunction with heart failure within six months of right ventricular septal pacing. The patient was upgraded to CRT-D, and one of the pacing leads was implanted in the His bundle area. Selective His bundle pacing led to normalization of QRS duration and a significant improvement of heart failure symptoms. Echocardiography performed after three months showed normalized left ventricular function.
Název v anglickém jazyce
Pacing-induced right ventricular cardiomyopathy resynchronized using His bundle pacing
Popis výsledku anglicky
Permanent unifocal right ventricular pacing can lead to ventricular dyssynchrony with subsequent dysfunction of the left ventricle, which can lead to heart failure. Heart failure caused by right ventricular pacing was traditionally associated with pacing from the apex of the right ventricle. Over the last two decades, significant efforts have been made to find alternative pacing sites that can reduce or prevent the risk of heart failure. Based on the latest findings, pacing the His bundle area appears extremely promising. In this case report, we present a 79-year-old male, who developed left ventricular dysfunction with heart failure within six months of right ventricular septal pacing. The patient was upgraded to CRT-D, and one of the pacing leads was implanted in the His bundle area. Selective His bundle pacing led to normalization of QRS duration and a significant improvement of heart failure symptoms. Echocardiography performed after three months showed normalized left ventricular function.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
30201 - Cardiac and Cardiovascular systems
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2020
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Cor et Vasa
ISSN
0010-8650
e-ISSN
—
Svazek periodika
62
Číslo periodika v rámci svazku
1
Stát vydavatele periodika
CZ - Česká republika
Počet stran výsledku
5
Strana od-do
80-84
Kód UT WoS článku
000517557800015
EID výsledku v databázi Scopus
2-s2.0-85087941553