Intrastromal Lenticule Rotation for the Treatment of High Astigmatism
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216208%3A11120%2F20%3A43920266" target="_blank" >RIV/00216208:11120/20:43920266 - isvavai.cz</a>
Výsledek na webu
<a href="https://doi.org/10.3928/1081597X-20200506-02" target="_blank" >https://doi.org/10.3928/1081597X-20200506-02</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.3928/1081597X-20200506-02" target="_blank" >10.3928/1081597X-20200506-02</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Intrastromal Lenticule Rotation for the Treatment of High Astigmatism
Popis výsledku v původním jazyce
PURPOSE: To describe the first clinical case using intrastromal lenticule rotation to surgically correct high astigmatism in an amblyopic eye. METHODS: A 31-year-old woman with mixed astigmatism of +2.00 -5.00 x 10 degrees (spherical equivalent -0.50 diopters [D]) in her left eye, uncorrected distance visual acuity (UDVA) of 0.8 logMAR, and corrected distance visual acuity (CDVA) of 0.7 logMAR underwent refractive lenticule rotation surgery. RESULTS: Postoperative refractive astigmatism changed to 0.00 D cylinder. There was a postoperative myopic shift and her spherical equivalent refraction was -4.00 D at 1 week, -3.75 D at 1 month, and -3.25 D at 3 and 6 months. The patient noted a slight improvement in UDVA and a significant improvement in her uncorrected near visual acuity from Jaeger 13 (> 1.0 logMAR) to Jaeger 5 (0.3 logMAR) at 1 and 3 months and subsequently to Jaeger 2 (0.1 logMAR). CONCLUSIONS: To the best of the authors' knowledge, this is the first clinical case of astigmatism correction using small incision lenticule extraction lenticule rotation. This case of an amblyopic eye demonstrates that the procedure is capable of correcting both corneal and refractive astigmatism, and the short-term result seems stable.
Název v anglickém jazyce
Intrastromal Lenticule Rotation for the Treatment of High Astigmatism
Popis výsledku anglicky
PURPOSE: To describe the first clinical case using intrastromal lenticule rotation to surgically correct high astigmatism in an amblyopic eye. METHODS: A 31-year-old woman with mixed astigmatism of +2.00 -5.00 x 10 degrees (spherical equivalent -0.50 diopters [D]) in her left eye, uncorrected distance visual acuity (UDVA) of 0.8 logMAR, and corrected distance visual acuity (CDVA) of 0.7 logMAR underwent refractive lenticule rotation surgery. RESULTS: Postoperative refractive astigmatism changed to 0.00 D cylinder. There was a postoperative myopic shift and her spherical equivalent refraction was -4.00 D at 1 week, -3.75 D at 1 month, and -3.25 D at 3 and 6 months. The patient noted a slight improvement in UDVA and a significant improvement in her uncorrected near visual acuity from Jaeger 13 (> 1.0 logMAR) to Jaeger 5 (0.3 logMAR) at 1 and 3 months and subsequently to Jaeger 2 (0.1 logMAR). CONCLUSIONS: To the best of the authors' knowledge, this is the first clinical case of astigmatism correction using small incision lenticule extraction lenticule rotation. This case of an amblyopic eye demonstrates that the procedure is capable of correcting both corneal and refractive astigmatism, and the short-term result seems stable.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
30207 - Ophthalmology
Návaznosti výsledku
Projekt
—
Návaznosti
V - Vyzkumna aktivita podporovana z jinych verejnych zdroju
Ostatní
Rok uplatnění
2020
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Journal of Refractive Surgery
ISSN
1081-597X
e-ISSN
—
Svazek periodika
36
Číslo periodika v rámci svazku
6
Stát vydavatele periodika
US - Spojené státy americké
Počet stran výsledku
4
Strana od-do
415-418
Kód UT WoS článku
000540708900008
EID výsledku v databázi Scopus
2-s2.0-85086354676