In vitro simulation of acute feto-fetal transfusion in case of single intrauterine fetal death in monochorionic twins
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216208%3A11120%2F21%3A43921827" target="_blank" >RIV/00216208:11120/21:43921827 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/00023698:_____/21:N0000007 RIV/00216208:11140/21:10427934
Výsledek na webu
<a href="https://doi.org/10.1016/j.placenta.2021.05.004" target="_blank" >https://doi.org/10.1016/j.placenta.2021.05.004</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.placenta.2021.05.004" target="_blank" >10.1016/j.placenta.2021.05.004</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
In vitro simulation of acute feto-fetal transfusion in case of single intrauterine fetal death in monochorionic twins
Popis výsledku v původním jazyce
INTRODUCTION: Thanks to shared circulation in monochorionic twins, single intrauterine fetal death (IUD) may lead to acute feto-fetal transfusion (aFFTR). The objective of the study was to describe our model of aFFTR simulation after IUD in monochorionic (MC) twins. METHODS: Prospective study analyzed 99 fresh MC placentas with the physiological course. A specially designed protocol was used for the preparation and analysis of the placentas. A pair of infusion sets fixed together using a mechanical mercury sphygmomanometer cuff was connected to the cannulated umbilical arteries. The tonometer was pressurized up to 30 and 40 mmHg. A positive finding of aFFTR was determined as the amount exceeding 1 ml of dye flowed out of the umbilical cord simulating a dead fetus. The number and types of anastomoses, types, and distances between cords insertions, and the size of the placental areas for each fetus were also statistically analyzed. The placental angioarchitecture with and without proven aFFTR was statistically compared, odds ratio (OR) and multivariable logistic analysis were performed. RESULTS: A total of 49/99 (49.5%) cases of aFFTR was proven, and the average transfusion time of 1 ml was 30 s (19-46 s). aFFTR was present in 49/78 (62.8%) of placentas with arterio-arterial (AA) anastomosis. The median diameter of AA anastomoses with the present, and absent aFFTRF was 2.0 mm and 1.0 mm, respectively. The proven interfetal transfusion was 8%, 31%, and 61% in AA anastomoses with a diameter below 0,5 mm, 0,5-1,5 mm, and above 1,5 mm, respectively (p < 0,001). AA anastomoses diameter >1.5 mm had OR of 44.2 (95% CI 5.54-352.39). In the case of coexistence of AA anastomosis and umbilical cord distance LESS-THAN OR EQUAL TO5th percentile, the aFFTRF occurred in 90.9%. DISCUSSION: The potential risk of aFFTR in monochorionic twins is mainly due to the presence and nature of AA anastomoses. The diameter and length of the vessels play a crucial role, which is clinically related to the distance of the umbilical cords insertions.
Název v anglickém jazyce
In vitro simulation of acute feto-fetal transfusion in case of single intrauterine fetal death in monochorionic twins
Popis výsledku anglicky
INTRODUCTION: Thanks to shared circulation in monochorionic twins, single intrauterine fetal death (IUD) may lead to acute feto-fetal transfusion (aFFTR). The objective of the study was to describe our model of aFFTR simulation after IUD in monochorionic (MC) twins. METHODS: Prospective study analyzed 99 fresh MC placentas with the physiological course. A specially designed protocol was used for the preparation and analysis of the placentas. A pair of infusion sets fixed together using a mechanical mercury sphygmomanometer cuff was connected to the cannulated umbilical arteries. The tonometer was pressurized up to 30 and 40 mmHg. A positive finding of aFFTR was determined as the amount exceeding 1 ml of dye flowed out of the umbilical cord simulating a dead fetus. The number and types of anastomoses, types, and distances between cords insertions, and the size of the placental areas for each fetus were also statistically analyzed. The placental angioarchitecture with and without proven aFFTR was statistically compared, odds ratio (OR) and multivariable logistic analysis were performed. RESULTS: A total of 49/99 (49.5%) cases of aFFTR was proven, and the average transfusion time of 1 ml was 30 s (19-46 s). aFFTR was present in 49/78 (62.8%) of placentas with arterio-arterial (AA) anastomosis. The median diameter of AA anastomoses with the present, and absent aFFTRF was 2.0 mm and 1.0 mm, respectively. The proven interfetal transfusion was 8%, 31%, and 61% in AA anastomoses with a diameter below 0,5 mm, 0,5-1,5 mm, and above 1,5 mm, respectively (p < 0,001). AA anastomoses diameter >1.5 mm had OR of 44.2 (95% CI 5.54-352.39). In the case of coexistence of AA anastomosis and umbilical cord distance LESS-THAN OR EQUAL TO5th percentile, the aFFTRF occurred in 90.9%. DISCUSSION: The potential risk of aFFTR in monochorionic twins is mainly due to the presence and nature of AA anastomoses. The diameter and length of the vessels play a crucial role, which is clinically related to the distance of the umbilical cords insertions.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
30209 - Paediatrics
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2021
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Placenta
ISSN
0143-4004
e-ISSN
—
Svazek periodika
111
Číslo periodika v rámci svazku
August
Stát vydavatele periodika
GB - Spojené království Velké Británie a Severního Irska
Počet stran výsledku
7
Strana od-do
26-32
Kód UT WoS článku
000690348500004
EID výsledku v databázi Scopus
2-s2.0-85107951489