Methods of Motion Assessment of Upper Limb for Rehabilitation Application
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216208%3A11130%2F18%3A10383506" target="_blank" >RIV/00216208:11130/18:10383506 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/00064203:_____/18:10383506
Výsledek na webu
<a href="https://doi.org/10.23919/AE.2018.8501423" target="_blank" >https://doi.org/10.23919/AE.2018.8501423</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.23919/AE.2018.8501423" target="_blank" >10.23919/AE.2018.8501423</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Methods of Motion Assessment of Upper Limb for Rehabilitation Application
Popis výsledku v původním jazyce
The aim of this paper is to describe methods proposed for motion capture subsystem of smart orthosis for quantitative evaluation of movement activity of upper limbs during a rehabilitation process carried out at a clinic or at home. To quantify the description of motion we used methods of evaluation of the relationship between measured variables and nonlinear methods. To test the functionality of the methods, we compared the movement of the dominant and nondominant limbs, assuming cyclical and acyclic movement, to obtain the expected values for a healthy population. In accordance with the goal, a group of cyclic and non-cyclic movements common to the home environment were proposed. The movements were divided according to the activities performed during sitting, standing and walking. It was: pen writing, typing on the keyboard / using the mouse, eating with a spoon and eating a croissant combing, lifting weights, reading a book, etc. Twenty healthy subjects participated in the study. Four gyro-accelerometers (Xsens Technologies B.V.) attached to the forearms and upper arms of both upper limbs were used to record the upper limb movements. The results show that the calculated values of dominant and non-dominant limb parameters differ significantly in most movements. The motion capture subsystem which uses the proposed methods can be used to evaluate the physical activity for quantification of the evaluation of the rehabilitation process, and thus, it finds use in practice.
Název v anglickém jazyce
Methods of Motion Assessment of Upper Limb for Rehabilitation Application
Popis výsledku anglicky
The aim of this paper is to describe methods proposed for motion capture subsystem of smart orthosis for quantitative evaluation of movement activity of upper limbs during a rehabilitation process carried out at a clinic or at home. To quantify the description of motion we used methods of evaluation of the relationship between measured variables and nonlinear methods. To test the functionality of the methods, we compared the movement of the dominant and nondominant limbs, assuming cyclical and acyclic movement, to obtain the expected values for a healthy population. In accordance with the goal, a group of cyclic and non-cyclic movements common to the home environment were proposed. The movements were divided according to the activities performed during sitting, standing and walking. It was: pen writing, typing on the keyboard / using the mouse, eating with a spoon and eating a croissant combing, lifting weights, reading a book, etc. Twenty healthy subjects participated in the study. Four gyro-accelerometers (Xsens Technologies B.V.) attached to the forearms and upper arms of both upper limbs were used to record the upper limb movements. The results show that the calculated values of dominant and non-dominant limb parameters differ significantly in most movements. The motion capture subsystem which uses the proposed methods can be used to evaluate the physical activity for quantification of the evaluation of the rehabilitation process, and thus, it finds use in practice.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
30211 - Orthopaedics
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2018
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
2018 23rd International Conference on Applied Electronics (AE)
ISBN
978-80-261-0722-4
ISSN
1803-7232
e-ISSN
neuvedeno
Počet stran výsledku
4
Strana od-do
89-92
Název nakladatele
IEEE
Místo vydání
New York
Místo konání akce
Pilsen
Datum konání akce
11. 8. 2018
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
000450228600021