Continuous glucose monitoring as a screening tool for neonatal hypoglycemia in infants of diabetic mothers
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216208%3A11130%2F20%3A10395824" target="_blank" >RIV/00216208:11130/20:10395824 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/68407700:21260/20:00329245 RIV/00064203:_____/20:10395824
Výsledek na webu
<a href="https://verso.is.cuni.cz/pub/verso.fpl?fname=obd_publikace_handle&handle=ZL~9UZq4yM" target="_blank" >https://verso.is.cuni.cz/pub/verso.fpl?fname=obd_publikace_handle&handle=ZL~9UZq4yM</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1080/14767058.2018.1533941" target="_blank" >10.1080/14767058.2018.1533941</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Continuous glucose monitoring as a screening tool for neonatal hypoglycemia in infants of diabetic mothers
Popis výsledku v původním jazyce
OBJECTIVE: To assess the plausibility of using the continuous glucose monitoring as a sole source of data for the screening of the neonatal hypoglycemia. STUDY DESIGN: Infants of mothers with diabetes were screened for neonatal hypoglycemia (less than 2.5 mmol/l after 4 h of life). Initial measurement was performed using point of care analyzer. We applied continuous glucose monitoring system subsequently. Infants were monitored up to 5 days or until discharge. RESULTS: Out of 32 infants 11 had postnatal hypoglycemia resolved within 12 h of life. Two infants had hypoglycemia found due to continuous glucose monitoring after 24 h of life when sufficient feeding was established and they did not show any signs of hypoglycemia. We did not have any false negative measurements. No infant showed clinical signs of neonatal hypoglycemia. CONCLUSIONS: Continuous glucose monitoring is plausible and safe to use for screening of neonatal hypoglycemia. It operates well within the range that is accepted as safe for neurodevelopment. In addition, it can be used after first day of life where regular screening ends. Limitation of this method is possible alarm negligence of caregivers.
Název v anglickém jazyce
Continuous glucose monitoring as a screening tool for neonatal hypoglycemia in infants of diabetic mothers
Popis výsledku anglicky
OBJECTIVE: To assess the plausibility of using the continuous glucose monitoring as a sole source of data for the screening of the neonatal hypoglycemia. STUDY DESIGN: Infants of mothers with diabetes were screened for neonatal hypoglycemia (less than 2.5 mmol/l after 4 h of life). Initial measurement was performed using point of care analyzer. We applied continuous glucose monitoring system subsequently. Infants were monitored up to 5 days or until discharge. RESULTS: Out of 32 infants 11 had postnatal hypoglycemia resolved within 12 h of life. Two infants had hypoglycemia found due to continuous glucose monitoring after 24 h of life when sufficient feeding was established and they did not show any signs of hypoglycemia. We did not have any false negative measurements. No infant showed clinical signs of neonatal hypoglycemia. CONCLUSIONS: Continuous glucose monitoring is plausible and safe to use for screening of neonatal hypoglycemia. It operates well within the range that is accepted as safe for neurodevelopment. In addition, it can be used after first day of life where regular screening ends. Limitation of this method is possible alarm negligence of caregivers.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
30105 - Physiology (including cytology)
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2020
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
The Journal of Maternal-Fetal & Neonatal Medicine
ISSN
1476-7058
e-ISSN
—
Svazek periodika
33
Číslo periodika v rámci svazku
11
Stát vydavatele periodika
GB - Spojené království Velké Británie a Severního Irska
Počet stran výsledku
6
Strana od-do
1889-1894
Kód UT WoS článku
000521652200012
EID výsledku v databázi Scopus
2-s2.0-85059021185