Acquired primary hemostasis pathology detected by platelet function analyzer 200 seen during extracorporeal membrane oxygenation is sufficient to prevent circuit thrombosis: A pilot study
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216208%3A11130%2F20%3A10412685" target="_blank" >RIV/00216208:11130/20:10412685 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/00064203:_____/20:10412685
Výsledek na webu
<a href="https://verso.is.cuni.cz/pub/verso.fpl?fname=obd_publikace_handle&handle=3MeBWEo2nR" target="_blank" >https://verso.is.cuni.cz/pub/verso.fpl?fname=obd_publikace_handle&handle=3MeBWEo2nR</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.healun.2020.05.015" target="_blank" >10.1016/j.healun.2020.05.015</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Acquired primary hemostasis pathology detected by platelet function analyzer 200 seen during extracorporeal membrane oxygenation is sufficient to prevent circuit thrombosis: A pilot study
Popis výsledku v původním jazyce
Extracorporeal membrane oxygenation (ECMO) used during lung transplantation surgery produces primary hemostasis pathology detected by a platelet function analyzer (PFA) 200. The PFA 200 results return to the pre-operative values soon after ECMO explantation. This phenomenon of primary hemostasis pathology detected by the PFA 200 was successfully used to prevent circuit thrombosis in patients on prolonged ECMO with respiratory or cardiac failure without the use of unfractionated heparin.
Název v anglickém jazyce
Acquired primary hemostasis pathology detected by platelet function analyzer 200 seen during extracorporeal membrane oxygenation is sufficient to prevent circuit thrombosis: A pilot study
Popis výsledku anglicky
Extracorporeal membrane oxygenation (ECMO) used during lung transplantation surgery produces primary hemostasis pathology detected by a platelet function analyzer (PFA) 200. The PFA 200 results return to the pre-operative values soon after ECMO explantation. This phenomenon of primary hemostasis pathology detected by the PFA 200 was successfully used to prevent circuit thrombosis in patients on prolonged ECMO with respiratory or cardiac failure without the use of unfractionated heparin.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
30223 - Anaesthesiology
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2020
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
The Journal of Heart and Lung Transplantation
ISSN
1053-2498
e-ISSN
—
Svazek periodika
39
Číslo periodika v rámci svazku
9
Stát vydavatele periodika
US - Spojené státy americké
Počet stran výsledku
3
Strana od-do
980-982
Kód UT WoS článku
000568918000017
EID výsledku v databázi Scopus
2-s2.0-85090138640