A comparative analysis of imaging-based algorithms for detecting focal cortical dysplasia type II in children
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216208%3A11130%2F25%3A10500483" target="_blank" >RIV/00216208:11130/25:10500483 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/00064203:_____/25:10500483
Výsledek na webu
<a href="https://verso.is.cuni.cz/pub/verso.fpl?fname=obd_publikace_handle&handle=fAh~Dv5PaG" target="_blank" >https://verso.is.cuni.cz/pub/verso.fpl?fname=obd_publikace_handle&handle=fAh~Dv5PaG</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1038/s41598-025-16015-3" target="_blank" >10.1038/s41598-025-16015-3</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
A comparative analysis of imaging-based algorithms for detecting focal cortical dysplasia type II in children
Popis výsledku v původním jazyce
Focal cortical dysplasia (FCD) is the leading cause of drug-resistant epilepsy (DRE) in pediatric patients. Accurate detection of FCDs is crucial for successful surgical outcomes, yet remains challenging due to frequently subtle MRI findings, especially in children, whose brain morphology undergoes significant developmental changes. Automated detection algorithms have the potential to improve diagnostic precision, particularly in cases, where standard visual assessment fails. This study aimed to evaluate the performance of automated algorithms in detecting FCD type II in pediatric patients and to examine the impact of adult versus pediatric templates on detection accuracy. MRI data from 23 surgical pediatric patients with histologically confirmed FCD type II were retrospectively analyzed. Three imaging-based detection algorithms were applied to T1-weighted images, each targeting key structural features: cortical thickness, gray matter intensity (extension), and gray-white matter junction blurring. Their performance was assessed using adult and pediatric healthy controls templates, with validation against both predictive radiological ROIs (PRR) and post-resection cavities (PRC). The junction algorithm achieved the highest median dice score (0.028, IQR 0.038, p < 0.01 when compared with other algorithms) and detected relevant clusters even in MRI-negative cases. The adult template (median dice score 0.013, IQR 0.027) significantly outperformed the pediatric template (0.0032, IQR 0.023) (p < 0.001), highlighting the importance of template consistency. Despite superior performance of the adult template, its use in pediatric populations may introduce bias, as it does not account for age-specific morphological features such as cortical maturation and incomplete myelination. Automated algorithms, especially those targeting junction blurring, enhance FCD detection in pediatric populations. These algorithms may serve as valuable decision-support tools, particularly in settings where neuroradiological expertise is limited.
Název v anglickém jazyce
A comparative analysis of imaging-based algorithms for detecting focal cortical dysplasia type II in children
Popis výsledku anglicky
Focal cortical dysplasia (FCD) is the leading cause of drug-resistant epilepsy (DRE) in pediatric patients. Accurate detection of FCDs is crucial for successful surgical outcomes, yet remains challenging due to frequently subtle MRI findings, especially in children, whose brain morphology undergoes significant developmental changes. Automated detection algorithms have the potential to improve diagnostic precision, particularly in cases, where standard visual assessment fails. This study aimed to evaluate the performance of automated algorithms in detecting FCD type II in pediatric patients and to examine the impact of adult versus pediatric templates on detection accuracy. MRI data from 23 surgical pediatric patients with histologically confirmed FCD type II were retrospectively analyzed. Three imaging-based detection algorithms were applied to T1-weighted images, each targeting key structural features: cortical thickness, gray matter intensity (extension), and gray-white matter junction blurring. Their performance was assessed using adult and pediatric healthy controls templates, with validation against both predictive radiological ROIs (PRR) and post-resection cavities (PRC). The junction algorithm achieved the highest median dice score (0.028, IQR 0.038, p < 0.01 when compared with other algorithms) and detected relevant clusters even in MRI-negative cases. The adult template (median dice score 0.013, IQR 0.027) significantly outperformed the pediatric template (0.0032, IQR 0.023) (p < 0.001), highlighting the importance of template consistency. Despite superior performance of the adult template, its use in pediatric populations may introduce bias, as it does not account for age-specific morphological features such as cortical maturation and incomplete myelination. Automated algorithms, especially those targeting junction blurring, enhance FCD detection in pediatric populations. These algorithms may serve as valuable decision-support tools, particularly in settings where neuroradiological expertise is limited.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
30103 - Neurosciences (including psychophysiology)
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2025
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Scientific Reports
ISSN
2045-2322
e-ISSN
2045-2322
Svazek periodika
15
Číslo periodika v rámci svazku
1
Stát vydavatele periodika
GB - Spojené království Velké Británie a Severního Irska
Počet stran výsledku
15
Strana od-do
29946
Kód UT WoS článku
001551657500012
EID výsledku v databázi Scopus
2-s2.0-105013253498