Pulmonary imaging using dual-energy CT, a role of the assessment of iodine and air distribution
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216208%3A11140%2F11%3A10106855" target="_blank" >RIV/00216208:11140/11:10106855 - isvavai.cz</a>
Výsledek na webu
<a href="http://www.sciencedirect.com/science/article/pii/S0720048X09004756" target="_blank" >http://www.sciencedirect.com/science/article/pii/S0720048X09004756</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.ejrad.2009.08.005" target="_blank" >10.1016/j.ejrad.2009.08.005</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Pulmonary imaging using dual-energy CT, a role of the assessment of iodine and air distribution
Popis výsledku v původním jazyce
We used the data of 50 CT examinations performed due to suspected pulmonary embolism with any pathological finding except consolidation of the parenchyma. The patients underwent CT angiography of the pulmonary arteries on a dual-source CT (DSCT), with the two tubes independently operated at 140 and 80 kV. By exploiting the dual-energy information, iodine distribution maps were obtained in addition to the conventional CT images which served as a marker of pulmonary perfusion. Minimum intensity projections (MinIP) were used as a marker of air content. By comparing the iodine distribution maps and MinIP images, it was possible to differentiate between the following templates of lung parenchyma: A--normal iodine and air distribution; B--iodine content deficit with minimal or with no redistribution of air; C--reduced iodine content and increased content of air; D--deficit of iodine content and increased content of air; E--increased iodine content and normal content of air; F--increased iodi
Název v anglickém jazyce
Pulmonary imaging using dual-energy CT, a role of the assessment of iodine and air distribution
Popis výsledku anglicky
We used the data of 50 CT examinations performed due to suspected pulmonary embolism with any pathological finding except consolidation of the parenchyma. The patients underwent CT angiography of the pulmonary arteries on a dual-source CT (DSCT), with the two tubes independently operated at 140 and 80 kV. By exploiting the dual-energy information, iodine distribution maps were obtained in addition to the conventional CT images which served as a marker of pulmonary perfusion. Minimum intensity projections (MinIP) were used as a marker of air content. By comparing the iodine distribution maps and MinIP images, it was possible to differentiate between the following templates of lung parenchyma: A--normal iodine and air distribution; B--iodine content deficit with minimal or with no redistribution of air; C--reduced iodine content and increased content of air; D--deficit of iodine content and increased content of air; E--increased iodine content and normal content of air; F--increased iodi
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
FP - Ostatní lékařské obory
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2011
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
European Journal of Radiology
ISSN
0720-048X
e-ISSN
—
Svazek periodika
77
Číslo periodika v rámci svazku
2
Stát vydavatele periodika
NL - Nizozemsko
Počet stran výsledku
7
Strana od-do
287-293
Kód UT WoS článku
000286623100018
EID výsledku v databázi Scopus
—