Different cardiac loading conditions and haemodynamic monitoring in animal

Identifikátory výsledku

Alternativní jazyky

  • Jazyk výsledku

    angličtina

  • Název v původním jazyce

    Different cardiac loading conditions and haemodynamic monitoring in animal

  • Popis výsledku v původním jazyce

    Objective: To develop models of various cardiac loading conditions in an experimental study. Materials and methods: A total of 78 piglets, average weight 24kg were divided into 4 groups under different cardiac loading conditions: Group A were spontaneously breathing pigs without haemodynamic changes, Group B were ventilated animals with increased left ventricular afterload, Group C ventilated with increased right ventricular preload and Group D ventilated with increased afterload of both heart ventricles. Haemodynamic parameters were invasively measured at 60 and 120 minutes. Results: Groups B, C and D demonstrated higher preload of both ventricles, compared with Group A. Group C demonstrated higher preload and afterload of both ventricles in comparison with Groups B and D. Conclusion: Haemodynamic measured data confirmed the expected changes in cardiac loading and corresponded to human clinical situations. These models may be used for future experimental haemodynamic studies.

  • Název v anglickém jazyce

    Different cardiac loading conditions and haemodynamic monitoring in animal

  • Popis výsledku anglicky

    Objective: To develop models of various cardiac loading conditions in an experimental study. Materials and methods: A total of 78 piglets, average weight 24kg were divided into 4 groups under different cardiac loading conditions: Group A were spontaneously breathing pigs without haemodynamic changes, Group B were ventilated animals with increased left ventricular afterload, Group C ventilated with increased right ventricular preload and Group D ventilated with increased afterload of both heart ventricles. Haemodynamic parameters were invasively measured at 60 and 120 minutes. Results: Groups B, C and D demonstrated higher preload of both ventricles, compared with Group A. Group C demonstrated higher preload and afterload of both ventricles in comparison with Groups B and D. Conclusion: Haemodynamic measured data confirmed the expected changes in cardiac loading and corresponded to human clinical situations. These models may be used for future experimental haemodynamic studies.

Klasifikace

  • Druh

    Jx - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)

  • CEP obor

    FG - Pediatrie

  • OECD FORD obor

Návaznosti výsledku

  • Projekt

    Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.

  • Návaznosti

    P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
    Z - Vyzkumny zamer (s odkazem do CEZ)
    S - Specificky vyzkum na vysokych skolach

Ostatní

  • Rok uplatnění

    2012

  • Kód důvěrnosti údajů

    S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů

Údaje specifické pro druh výsledku

  • Název periodika

    Bratislavske Lekarske Listy

  • ISSN

    0006-9248

  • e-ISSN

  • Svazek periodika

    113

  • Číslo periodika v rámci svazku

    3

  • Stát vydavatele periodika

    SK - Slovenská republika

  • Počet stran výsledku

    4

  • Strana od-do

    133-136