Iodine Content Analysis Using Dual-Energy Computed Tomography as a Biomarker of Transitional Cell Carcinoma, an Experience with Separation of the Clotted Blood and Tumorous Tissue
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216208%3A11140%2F18%3A10366605" target="_blank" >RIV/00216208:11140/18:10366605 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/00669806:_____/18:10366605
Výsledek na webu
<a href="http://ar.iiarjournals.org/content/38/1/541.abstract" target="_blank" >http://ar.iiarjournals.org/content/38/1/541.abstract</a>
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Iodine Content Analysis Using Dual-Energy Computed Tomography as a Biomarker of Transitional Cell Carcinoma, an Experience with Separation of the Clotted Blood and Tumorous Tissue
Popis výsledku v původním jazyce
Background/Aim: The aim of this study was to evaluate the possibility to discriminate the blood clot from tumorous tissue in the assessment of transitional cell carcinoma (TCC), when CT data are used only from single-phase dual-energy CT (DECT). Materials and Methods: A total of 18 patients were included into the retrospective analysis of the prospectively collected data (the average age was 67.3 years, range=62-79 years, 12 males, 6 females). DECT was performed in all patients after intravenous administration of the iodinated contrast material. DECT analysis using three-material decomposition algorithm was used to discriminate blood and enhancing tumorous tissue. In all patients, TCC was detected and subsequently kidney surgery or endoscopy was performed within the next two weeks. The findings were compared with DECT results. Results: In our cohort of patients we found 9 TCC of the renal pelvis or ureter and 7 TCC of the urinary bladder. The accuracy of the TCC detection was 94% (17/18). The presence of coagulated blood within the urinary collecting system together with a tumor was detected in 7 CT examinations. The blood coagulum without a confirmed malignant tumor was found in one case with false positive DECT finding. In other 6 cases bleeding was confirmed during surgery or endoscopy (accuracy 87%). Conclusion: The dual-energy data analysis enables discrimination of a blood clot from tumorous tissue. It helps in detection of UCC in cases when the excretion potential of the kidneys is decreased due to fulfillment of the collecting system with blood clots.
Název v anglickém jazyce
Iodine Content Analysis Using Dual-Energy Computed Tomography as a Biomarker of Transitional Cell Carcinoma, an Experience with Separation of the Clotted Blood and Tumorous Tissue
Popis výsledku anglicky
Background/Aim: The aim of this study was to evaluate the possibility to discriminate the blood clot from tumorous tissue in the assessment of transitional cell carcinoma (TCC), when CT data are used only from single-phase dual-energy CT (DECT). Materials and Methods: A total of 18 patients were included into the retrospective analysis of the prospectively collected data (the average age was 67.3 years, range=62-79 years, 12 males, 6 females). DECT was performed in all patients after intravenous administration of the iodinated contrast material. DECT analysis using three-material decomposition algorithm was used to discriminate blood and enhancing tumorous tissue. In all patients, TCC was detected and subsequently kidney surgery or endoscopy was performed within the next two weeks. The findings were compared with DECT results. Results: In our cohort of patients we found 9 TCC of the renal pelvis or ureter and 7 TCC of the urinary bladder. The accuracy of the TCC detection was 94% (17/18). The presence of coagulated blood within the urinary collecting system together with a tumor was detected in 7 CT examinations. The blood coagulum without a confirmed malignant tumor was found in one case with false positive DECT finding. In other 6 cases bleeding was confirmed during surgery or endoscopy (accuracy 87%). Conclusion: The dual-energy data analysis enables discrimination of a blood clot from tumorous tissue. It helps in detection of UCC in cases when the excretion potential of the kidneys is decreased due to fulfillment of the collecting system with blood clots.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
30224 - Radiology, nuclear medicine and medical imaging
Návaznosti výsledku
Projekt
<a href="/cs/project/ED2.1.00%2F03.0076" target="_blank" >ED2.1.00/03.0076: Biomedicínské centrum Lékařské fakulty v Plzni</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2018
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Anticancer Research
ISSN
0250-7005
e-ISSN
—
Svazek periodika
38
Číslo periodika v rámci svazku
1
Stát vydavatele periodika
GR - Řecká republika
Počet stran výsledku
5
Strana od-do
541-545
Kód UT WoS článku
000419130100073
EID výsledku v databázi Scopus
2-s2.0-85039799998