Robotic Laser Tissue Soldering for Atraumatic Soft Tissue Fusion Guided by Fluorescent Nanothermometry
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216208%3A11140%2F25%3A10487754" target="_blank" >RIV/00216208:11140/25:10487754 - isvavai.cz</a>
Výsledek na webu
<a href="https://verso.is.cuni.cz/pub/verso.fpl?fname=obd_publikace_handle&handle=osF6ICxXTp" target="_blank" >https://verso.is.cuni.cz/pub/verso.fpl?fname=obd_publikace_handle&handle=osF6ICxXTp</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1002/advs.202406671" target="_blank" >10.1002/advs.202406671</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Robotic Laser Tissue Soldering for Atraumatic Soft Tissue Fusion Guided by Fluorescent Nanothermometry
Popis výsledku v původním jazyce
Minimally invasive surgical techniques, including endoscopic and robotic procedures, continue to revolutionize patient care, for their ability to minimize surgical trauma, thus promoting faster recovery and reduced hospital stays. Yet, the suturing of soft tissues ensuring damage-free tissue bonding during these procedures remains challenging due to missing haptics and the fulcrum effect. Laser tissue soldering has potential in overcoming these issues, offering atraumatic seamless tissue fusion. To ensure the precision and safety of laser tissue soldering, the study introduces feedback-controlled fluorescent nanothermometry-guided laser tissue soldering using nanoparticle-protein solders within endoscopic and robotic contexts. Temperature-sensitive fluorescent nanoparticles embedded in the solder provide surgeons with immediate feedback on tissue temperatures during laser application, all while within the confines of minimally invasive (robotic) surgical setups. By integrating fluorescent nanothermometry-guided laser tissue surgery into endoscopic and robotic surgery, the study paves the way for a new approach for safe and atraumatic soft tissue joining, especially in regions where traditional suturing is unfeasible.
Název v anglickém jazyce
Robotic Laser Tissue Soldering for Atraumatic Soft Tissue Fusion Guided by Fluorescent Nanothermometry
Popis výsledku anglicky
Minimally invasive surgical techniques, including endoscopic and robotic procedures, continue to revolutionize patient care, for their ability to minimize surgical trauma, thus promoting faster recovery and reduced hospital stays. Yet, the suturing of soft tissues ensuring damage-free tissue bonding during these procedures remains challenging due to missing haptics and the fulcrum effect. Laser tissue soldering has potential in overcoming these issues, offering atraumatic seamless tissue fusion. To ensure the precision and safety of laser tissue soldering, the study introduces feedback-controlled fluorescent nanothermometry-guided laser tissue soldering using nanoparticle-protein solders within endoscopic and robotic contexts. Temperature-sensitive fluorescent nanoparticles embedded in the solder provide surgeons with immediate feedback on tissue temperatures during laser application, all while within the confines of minimally invasive (robotic) surgical setups. By integrating fluorescent nanothermometry-guided laser tissue surgery into endoscopic and robotic surgery, the study paves the way for a new approach for safe and atraumatic soft tissue joining, especially in regions where traditional suturing is unfeasible.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
30212 - Surgery
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2025
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Advanced Science
ISSN
2198-3844
e-ISSN
2198-3844
Svazek periodika
12
Číslo periodika v rámci svazku
7
Stát vydavatele periodika
DE - Spolková republika Německo
Počet stran výsledku
14
Strana od-do
e2406671
Kód UT WoS článku
001393167800001
EID výsledku v databázi Scopus
2-s2.0-85218090994