Fotopické a skotopické evokované potenciály u pacientů s kongenitální stacionární šeroslepostí
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216208%3A11150%2F04%3A00002078" target="_blank" >RIV/00216208:11150/04:00002078 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Photopic and scotopic VEPs in patients with congenital stationary night-blindness
Popis výsledku v původním jazyce
Extended set of visual evoked potentials (VEPs) using pattern-reversal (PREPs), linear motion-onset and radial (expansion) motion-onset stimuli (M-VEPs) was used to verify congenital stationary night-blindness (CSNB) characteristics in 7 patients (compared to 7 age matched controls) in photopic conditions (luminance of 17 cd/m2). No differences were found in any of the M-VEPs, whilst PREPs displayed prolonged latencies in 3 of 7 CSNB patients Additionally, the PREPs and M-VEPs were tested in 3 normal and 3 CSNB subjects over large range of scotopic, mesopic and photopic luminances (from 0.0001 to 65.4 cd/m2). Both types of low luminance VEPs had distinctly increased luminance threshold needed for reliable VEPs eliciting in CSNB patients (0.06 cd/m2) when compared with controls (0.003 cd/m2). Thus, our pilot study proved that CSNB can be objectively detected also via scotopic VEP examination.
Název v anglickém jazyce
Photopic and scotopic VEPs in patients with congenital stationary night-blindness
Popis výsledku anglicky
Extended set of visual evoked potentials (VEPs) using pattern-reversal (PREPs), linear motion-onset and radial (expansion) motion-onset stimuli (M-VEPs) was used to verify congenital stationary night-blindness (CSNB) characteristics in 7 patients (compared to 7 age matched controls) in photopic conditions (luminance of 17 cd/m2). No differences were found in any of the M-VEPs, whilst PREPs displayed prolonged latencies in 3 of 7 CSNB patients Additionally, the PREPs and M-VEPs were tested in 3 normal and 3 CSNB subjects over large range of scotopic, mesopic and photopic luminances (from 0.0001 to 65.4 cd/m2). Both types of low luminance VEPs had distinctly increased luminance threshold needed for reliable VEPs eliciting in CSNB patients (0.06 cd/m2) when compared with controls (0.003 cd/m2). Thus, our pilot study proved that CSNB can be objectively detected also via scotopic VEP examination.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
FH - Neurologie, neurochirurgie, neurovědy
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/GA309%2F02%2F1134" target="_blank" >GA309/02/1134: Elektrofyziologické hodnocení věkově závislých změn zrakového vnímání člověka</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2004
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Documenta Ophthalmologica
ISSN
0012-4486
e-ISSN
—
Svazek periodika
109
Číslo periodika v rámci svazku
1
Stát vydavatele periodika
NL - Nizozemsko
Počet stran výsledku
7
Strana od-do
9-15
Kód UT WoS článku
—
EID výsledku v databázi Scopus
—