Název v původním jazyce
Mechanical properties of selfexpandable stents
Popis výsledku v původním jazyce
The stents or stentgrafts are the medical instruments used in invasive radiology for miniinvasive treatment of stenosis and aneurisms especially in the blood circulation system. We measured and compared the mechanical parameters of different selfexpandable Nitinol stents, which differed in the geometry, in the type of construction and in the diameter of the used wire. The results of measurements confirmed the theoretical assumptions that just the diameter of the Nitinol wire significantly influences therigidity and the level of compressibility of the stent as well. The compromise must be found between the required rigidity of the stent and the minimal size of the delivery system. The exact description of the relation between the mechanical propertiesand geometry and construction of the stents enables us to design the stent to fit the patient?s needs. The results of measurement are also necessary for the design and identification of the parameters of the models of the stents.
Název v anglickém jazyce
Mechanical properties of selfexpandable stents
Popis výsledku anglicky
The stents or stentgrafts are the medical instruments used in invasive radiology for miniinvasive treatment of stenosis and aneurisms especially in the blood circulation system. We measured and compared the mechanical parameters of different selfexpandable Nitinol stents, which differed in the geometry, in the type of construction and in the diameter of the used wire. The results of measurements confirmed the theoretical assumptions that just the diameter of the Nitinol wire significantly influences therigidity and the level of compressibility of the stent as well. The compromise must be found between the required rigidity of the stent and the minimal size of the delivery system. The exact description of the relation between the mechanical propertiesand geometry and construction of the stents enables us to design the stent to fit the patient?s needs. The results of measurement are also necessary for the design and identification of the parameters of the models of the stents.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
BO - Biofyzika
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2004
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Acta Medica (Hradec Králové)
ISSN
1211-4286
e-ISSN
—
Svazek periodika
47
Číslo periodika v rámci svazku
2
Stát vydavatele periodika
CZ - Česká republika
Počet stran výsledku
4
Strana od-do
303-306
Kód UT WoS článku
—
EID výsledku v databázi Scopus
—