Použití stabilografické plošiny a hodnocení metod pro další měření - pilotní studie
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216208%3A11150%2F07%3A00004106" target="_blank" >RIV/00216208:11150/07:00004106 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Use of stabilometric platform and evaluation of methods for further measurements - a pilot study
Popis výsledku v původním jazyce
Posture in a still stance has been quantified by changes in the center of pressure (COP), in both anterior-posterior (A/P) and medial-lateral (M/L) directions and measured on a single force platform (Bertec PRO VEC 5.0). The purpose of this study was toestimate the variance in error and the intrasession test-retest reliability, and to determine which measures shall be taken for further measurements, especially with adults age 65 and older. We used two types of approximation for the reliability coefficient. Firstly, we used the equation according to Blahuš (2) and secondly we used the Pearson?s correlation coefficient for test-retest measurements. The findings allow us to say, that the tests of quiet standing Double Narrow Stance Eyes Open (DNSEO) andDouble Narrow Stance Eyes Closed (DNSEC) are parallel, in the sense of parallel testing.
Název v anglickém jazyce
Use of stabilometric platform and evaluation of methods for further measurements - a pilot study
Popis výsledku anglicky
Posture in a still stance has been quantified by changes in the center of pressure (COP), in both anterior-posterior (A/P) and medial-lateral (M/L) directions and measured on a single force platform (Bertec PRO VEC 5.0). The purpose of this study was toestimate the variance in error and the intrasession test-retest reliability, and to determine which measures shall be taken for further measurements, especially with adults age 65 and older. We used two types of approximation for the reliability coefficient. Firstly, we used the equation according to Blahuš (2) and secondly we used the Pearson?s correlation coefficient for test-retest measurements. The findings allow us to say, that the tests of quiet standing Double Narrow Stance Eyes Open (DNSEO) andDouble Narrow Stance Eyes Closed (DNSEC) are parallel, in the sense of parallel testing.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
FP - Ostatní lékařské obory
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2007
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Acta Medica (Hradec Králové)
ISSN
1211-4286
e-ISSN
—
Svazek periodika
50
Číslo periodika v rámci svazku
2.
Stát vydavatele periodika
CZ - Česká republika
Počet stran výsledku
5
Strana od-do
139-143
Kód UT WoS článku
—
EID výsledku v databázi Scopus
—