Thermomechanical properties of nickel-titanium closed-coil springs and their implications for clinical practice
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216208%3A11150%2F14%3A10283992" target="_blank" >RIV/00216208:11150/14:10283992 - isvavai.cz</a>
Výsledek na webu
<a href="http://dx.doi.org/10.1016/j.ajodo.2014.05.025" target="_blank" >http://dx.doi.org/10.1016/j.ajodo.2014.05.025</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.ajodo.2014.05.025" target="_blank" >10.1016/j.ajodo.2014.05.025</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Thermomechanical properties of nickel-titanium closed-coil springs and their implications for clinical practice
Popis výsledku v původním jazyce
Introduction: The aim was to study nickel-titanium closed-coil springs in a clinically relevant test setting with respect to the accuracy of the "preactivation" for nickel-titanium closed-coil springs application and whether it is possible to keep activation forces constant during the whole time of treatment. Methods: We tested 10 types of springs from 5 manufacturers under clinically relevant conditions, allowing us to study the interactions between load and temperature over time. Hystereses were compared using t tests. Results: Springs with a large mechanical hysteresis also showed a large thermal hysteresis. After heating shock, these springs showed intensive force spikes and persistent high loads. Some springs showed negligible thermal and mechanical hysteresis. Such springs never showed any clinically significant persistent high loads. Conclusions: Springs with a large hysteresis were unable to keep activation forces constant during the whole time of treatment even after any pre-a
Název v anglickém jazyce
Thermomechanical properties of nickel-titanium closed-coil springs and their implications for clinical practice
Popis výsledku anglicky
Introduction: The aim was to study nickel-titanium closed-coil springs in a clinically relevant test setting with respect to the accuracy of the "preactivation" for nickel-titanium closed-coil springs application and whether it is possible to keep activation forces constant during the whole time of treatment. Methods: We tested 10 types of springs from 5 manufacturers under clinically relevant conditions, allowing us to study the interactions between load and temperature over time. Hystereses were compared using t tests. Results: Springs with a large mechanical hysteresis also showed a large thermal hysteresis. After heating shock, these springs showed intensive force spikes and persistent high loads. Some springs showed negligible thermal and mechanical hysteresis. Such springs never showed any clinically significant persistent high loads. Conclusions: Springs with a large hysteresis were unable to keep activation forces constant during the whole time of treatment even after any pre-a
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
BO - Biofyzika
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2014
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
American Journal of Orthodontics and Dentofacial Orthopedics
ISSN
0889-5406
e-ISSN
—
Svazek periodika
146
Číslo periodika v rámci svazku
3
Stát vydavatele periodika
US - Spojené státy americké
Počet stran výsledku
9
Strana od-do
319-327
Kód UT WoS článku
000341305800010
EID výsledku v databázi Scopus
—