Computed Tomography (CT)-Navigated Translumbar Hemodialysis Catheters: A 10-Year Single-Center Experience
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216208%3A11150%2F20%3A10419560" target="_blank" >RIV/00216208:11150/20:10419560 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/00179906:_____/20:10419560
Výsledek na webu
<a href="https://verso.is.cuni.cz/pub/verso.fpl?fname=obd_publikace_handle&handle=_R3s37dZbn" target="_blank" >https://verso.is.cuni.cz/pub/verso.fpl?fname=obd_publikace_handle&handle=_R3s37dZbn</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.12659/MSM.927723" target="_blank" >10.12659/MSM.927723</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Computed Tomography (CT)-Navigated Translumbar Hemodialysis Catheters: A 10-Year Single-Center Experience
Popis výsledku v původním jazyce
Background: In dialysis patients with exhausted usual central venous access sites, the translumbar hemodialysis catheter (TLC) provides a viable option for dialysis access. The technical success of catheter insertion, associated complications, and long-term patency of TLC were evaluated in this study. Material/Methods: This retrospective study included 37 patients with occluded central thoracic veins in whom 39 TLC implantation procedures were performed and 196 patients with internal jugular vein hemodialysis catheters (JVC). TLC implantation was performed as a hybrid procedure with computed tomography (CT)-navigated translumbar inferior vena cava cannulation and subsequent fluoroscopy-guided hemodialysis catheter placement. Results: The rates of technical success of the implantations and minor periprocedural complications were 97.4% and 10.3% in the TLC group and 98.6% and 4.2% in the JVC group, respectively. The median follow-up in the TLC and JVC groups was 673 days and 310 days, respectively. The primary-assisted patency at the 1-year and 3-year follow-up was 88.7% and 72.0% in the TLC group and 81.6% and 67.0% in the JVC group, respectively, with no statistically significant difference between the 2 groups. The incidence rate of infection-related and patency-related complications calculated for 1000 catheter-days was 0.15 and 0.11 in the TLC group and 0.33 and 0.25 in the JVC group, respectively. Conclusions: The CT-guided implantation of the TLC is a useful option to create dialysis access with a low complication rate and satisfactory long-term patency in patients without usual venous access.
Název v anglickém jazyce
Computed Tomography (CT)-Navigated Translumbar Hemodialysis Catheters: A 10-Year Single-Center Experience
Popis výsledku anglicky
Background: In dialysis patients with exhausted usual central venous access sites, the translumbar hemodialysis catheter (TLC) provides a viable option for dialysis access. The technical success of catheter insertion, associated complications, and long-term patency of TLC were evaluated in this study. Material/Methods: This retrospective study included 37 patients with occluded central thoracic veins in whom 39 TLC implantation procedures were performed and 196 patients with internal jugular vein hemodialysis catheters (JVC). TLC implantation was performed as a hybrid procedure with computed tomography (CT)-navigated translumbar inferior vena cava cannulation and subsequent fluoroscopy-guided hemodialysis catheter placement. Results: The rates of technical success of the implantations and minor periprocedural complications were 97.4% and 10.3% in the TLC group and 98.6% and 4.2% in the JVC group, respectively. The median follow-up in the TLC and JVC groups was 673 days and 310 days, respectively. The primary-assisted patency at the 1-year and 3-year follow-up was 88.7% and 72.0% in the TLC group and 81.6% and 67.0% in the JVC group, respectively, with no statistically significant difference between the 2 groups. The incidence rate of infection-related and patency-related complications calculated for 1000 catheter-days was 0.15 and 0.11 in the TLC group and 0.33 and 0.25 in the JVC group, respectively. Conclusions: The CT-guided implantation of the TLC is a useful option to create dialysis access with a low complication rate and satisfactory long-term patency in patients without usual venous access.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
30224 - Radiology, nuclear medicine and medical imaging
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2020
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Medical Science Monitor [online]
ISSN
1643-3750
e-ISSN
—
Svazek periodika
26
Číslo periodika v rámci svazku
December
Stát vydavatele periodika
US - Spojené státy americké
Počet stran výsledku
9
Strana od-do
e927723
Kód UT WoS článku
000599095400001
EID výsledku v databázi Scopus
2-s2.0-85096452758