Staining Performance of ALK and ROS1 Immunohistochemistry and Influence on Interpretation in Non-Small-Cell Lung Cancer
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216208%3A11150%2F20%3A10419578" target="_blank" >RIV/00216208:11150/20:10419578 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/00179906:_____/20:10419578
Výsledek na webu
<a href="https://verso.is.cuni.cz/pub/verso.fpl?fname=obd_publikace_handle&handle=KUlueXzZ6-" target="_blank" >https://verso.is.cuni.cz/pub/verso.fpl?fname=obd_publikace_handle&handle=KUlueXzZ6-</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.jmoldx.2020.09.006" target="_blank" >10.1016/j.jmoldx.2020.09.006</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Staining Performance of ALK and ROS1 Immunohistochemistry and Influence on Interpretation in Non-Small-Cell Lung Cancer
Popis výsledku v původním jazyce
Selection of non-small-cell lung cancer patients for treatment relies on the detection of expression of anaplastic lymphoma kinase (ALK) and ROS proto-oncogene 1 (ROS1) protein by immunohistochemistry (IHC). We evaluated staining performance for different IHC protocols and laboratory characteristics, and their influence on ALK and ROS1 interpretation during external quality assessment schemes between 2015 and 2018. Participants received five formalin-fixed, paraffin-embedded cases for staining by their routine protocol, whereafter at least two pathologists scored them simultaneously under a multihead microscope and awarded a graded expert staining score (ESS) from 1 to 5 points based on staining quality. European Conformity in Vitro Diagnostic kits (such as D5F3) revealed a better ALK ESS compared with laboratory-developed tests. ESS was indifferent to the applied antibody dilution or a recent protocol change. Lower ESSs were observed for higher antibody incubation times and temperatures. ESS for various ROS1 protocols were largely similar. Overall, for both markers, ESS improved over time and for repeated external quality assessment participation but was independent of laboratory setting or experience. Except for ROS1, ESS positively correlated with laboratory accreditation. IHC stains with lower ESS correlated with increased error rates in ALK and ROS1 interpretation and analysis failures. Laboratory characteristics differently affected staining quality and interpretation, and laboratories should assess both aspects, and less common protocols need improvement in staining performance.
Název v anglickém jazyce
Staining Performance of ALK and ROS1 Immunohistochemistry and Influence on Interpretation in Non-Small-Cell Lung Cancer
Popis výsledku anglicky
Selection of non-small-cell lung cancer patients for treatment relies on the detection of expression of anaplastic lymphoma kinase (ALK) and ROS proto-oncogene 1 (ROS1) protein by immunohistochemistry (IHC). We evaluated staining performance for different IHC protocols and laboratory characteristics, and their influence on ALK and ROS1 interpretation during external quality assessment schemes between 2015 and 2018. Participants received five formalin-fixed, paraffin-embedded cases for staining by their routine protocol, whereafter at least two pathologists scored them simultaneously under a multihead microscope and awarded a graded expert staining score (ESS) from 1 to 5 points based on staining quality. European Conformity in Vitro Diagnostic kits (such as D5F3) revealed a better ALK ESS compared with laboratory-developed tests. ESS was indifferent to the applied antibody dilution or a recent protocol change. Lower ESSs were observed for higher antibody incubation times and temperatures. ESS for various ROS1 protocols were largely similar. Overall, for both markers, ESS improved over time and for repeated external quality assessment participation but was independent of laboratory setting or experience. Except for ROS1, ESS positively correlated with laboratory accreditation. IHC stains with lower ESS correlated with increased error rates in ALK and ROS1 interpretation and analysis failures. Laboratory characteristics differently affected staining quality and interpretation, and laboratories should assess both aspects, and less common protocols need improvement in staining performance.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
30109 - Pathology
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2020
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Journal of Molecular Diagnostics
ISSN
1525-1578
e-ISSN
—
Svazek periodika
22
Číslo periodika v rámci svazku
12
Stát vydavatele periodika
US - Spojené státy americké
Počet stran výsledku
15
Strana od-do
1438-1452
Kód UT WoS článku
000591511100009
EID výsledku v databázi Scopus
2-s2.0-85096233053