Cardiac doses of accelerated partial breast irradiation with perioperative multicatheter interstitial brachytherapy
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216208%3A11150%2F21%3A10423515" target="_blank" >RIV/00216208:11150/21:10423515 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/00179906:_____/21:10423515
Výsledek na webu
<a href="https://verso.is.cuni.cz/pub/verso.fpl?fname=obd_publikace_handle&handle=-TIZBTfF4I" target="_blank" >https://verso.is.cuni.cz/pub/verso.fpl?fname=obd_publikace_handle&handle=-TIZBTfF4I</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1007/s00066-020-01699-5" target="_blank" >10.1007/s00066-020-01699-5</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Cardiac doses of accelerated partial breast irradiation with perioperative multicatheter interstitial brachytherapy
Popis výsledku v původním jazyce
Purpose To quantify mean heart dose (MHD) and doses to the left anterior descending artery (LAD) and left ventricle (LV) in a retrospective series of patients who underwent perioperative accelerated partial breast irradiation with multicatheter interstitial brachytherapy (MIB-APBI). Methods Sixty-eight patients with low-risk left breast cancer were treated with MIB-APBI at our institution between 2012 and 2017. Interstitial tubes were inserted during the tumorectomy and sentinel node biopsy and APBI was started 6 days later. The prescribed dose was 34Gy in 10 fractions (twice a day) to the clinical target volume (CTV). The heart, LAD, and LV were contoured and the distance between each structure and the CTV was measured. The MHD, mean and maximum LAD doses (LAD mean/max), and mean LV doses (LV mean) were calculated and corrected to biologically equivalent doses in 2-Gy fractionation (EQD2). We also evaluated the impact of the distance between the cardiac structures and the CTV and of the volume receiving the prescribed dose (V100) and high-dose volume (V150) on heart dosimetry. Results Mean EQD2 for MHD, LAD mean/max, and mean LV were 0.9 +/- 0.4Gy (range 0.3-2.2), 1.6 +/- 1.1Gy (range, 0.4-5.6), 2.6 +/- 1.9Gy (range, 0.7-9.2), and 1.3 +/- 0.6Gy (range, 0.5-3.4), respectively. MHD, LAD mean/max, and LV mean significantly correlated with the distance between the CTV and these structures, but all doses were below the recommended limits (German Society of Radiation Oncology; DEGRO). The MHD and LV mean were significantly dependent on V100. Conclusion Perioperative MIB-APBI resulted in low cardiac doses in our study. This finding provides further support for the value of this technique in well-selected patients with early-stage left breast cancer.
Název v anglickém jazyce
Cardiac doses of accelerated partial breast irradiation with perioperative multicatheter interstitial brachytherapy
Popis výsledku anglicky
Purpose To quantify mean heart dose (MHD) and doses to the left anterior descending artery (LAD) and left ventricle (LV) in a retrospective series of patients who underwent perioperative accelerated partial breast irradiation with multicatheter interstitial brachytherapy (MIB-APBI). Methods Sixty-eight patients with low-risk left breast cancer were treated with MIB-APBI at our institution between 2012 and 2017. Interstitial tubes were inserted during the tumorectomy and sentinel node biopsy and APBI was started 6 days later. The prescribed dose was 34Gy in 10 fractions (twice a day) to the clinical target volume (CTV). The heart, LAD, and LV were contoured and the distance between each structure and the CTV was measured. The MHD, mean and maximum LAD doses (LAD mean/max), and mean LV doses (LV mean) were calculated and corrected to biologically equivalent doses in 2-Gy fractionation (EQD2). We also evaluated the impact of the distance between the cardiac structures and the CTV and of the volume receiving the prescribed dose (V100) and high-dose volume (V150) on heart dosimetry. Results Mean EQD2 for MHD, LAD mean/max, and mean LV were 0.9 +/- 0.4Gy (range 0.3-2.2), 1.6 +/- 1.1Gy (range, 0.4-5.6), 2.6 +/- 1.9Gy (range, 0.7-9.2), and 1.3 +/- 0.6Gy (range, 0.5-3.4), respectively. MHD, LAD mean/max, and LV mean significantly correlated with the distance between the CTV and these structures, but all doses were below the recommended limits (German Society of Radiation Oncology; DEGRO). The MHD and LV mean were significantly dependent on V100. Conclusion Perioperative MIB-APBI resulted in low cardiac doses in our study. This finding provides further support for the value of this technique in well-selected patients with early-stage left breast cancer.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
30204 - Oncology
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2021
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Strahlentherapie und Onkologie
ISSN
0179-7158
e-ISSN
—
Svazek periodika
197
Číslo periodika v rámci svazku
4
Stát vydavatele periodika
DE - Spolková republika Německo
Počet stran výsledku
8
Strana od-do
288-295
Kód UT WoS článku
000579308100001
EID výsledku v databázi Scopus
2-s2.0-85092675167