Lung Point Sign in Ultrasound Diagnostics of Pneumothorax: Imitations and Variants
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216208%3A11150%2F21%3A10432367" target="_blank" >RIV/00216208:11150/21:10432367 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/44555601:13450/21:43896811 RIV/00179906:_____/21:10432367
Výsledek na webu
<a href="https://verso.is.cuni.cz/pub/verso.fpl?fname=obd_publikace_handle&handle=0htOENJzDJ" target="_blank" >https://verso.is.cuni.cz/pub/verso.fpl?fname=obd_publikace_handle&handle=0htOENJzDJ</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1155/2021/6897946" target="_blank" >10.1155/2021/6897946</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Lung Point Sign in Ultrasound Diagnostics of Pneumothorax: Imitations and Variants
Popis výsledku v původním jazyce
Background. Pulmonary ultrasound plays a key role in the diagnosis of pneumothorax in emergency and intensive-care medicine. The lung point sign has been generally considered a pathognomonic diagnostic sign. Recently, several other situations have been published that can mimic the lung point, as well as a few different variants of the true lung point sign. Materials and Methods. Based on years of monitoring the literature and collecting our database of ultrasound findings, we prepared a review of ultrasound findings mimicking the lung point sign and ultrasound variants of the true lung point sign. Results. We present four imitations of the lung point sign (physiological lung point sign, pseudo-lung point sign, bleb point sign, and pleurofascial point sign) and two variants of the true lung point sign (double lung point sign and hydro point sign) documented by images and video records. Conclusions. Knowledge of ultrasound imitations and variants of the lung point sign may increase the reliability of pneumothorax diagnosis and may reduce the risk of performing unindicated interventions.
Název v anglickém jazyce
Lung Point Sign in Ultrasound Diagnostics of Pneumothorax: Imitations and Variants
Popis výsledku anglicky
Background. Pulmonary ultrasound plays a key role in the diagnosis of pneumothorax in emergency and intensive-care medicine. The lung point sign has been generally considered a pathognomonic diagnostic sign. Recently, several other situations have been published that can mimic the lung point, as well as a few different variants of the true lung point sign. Materials and Methods. Based on years of monitoring the literature and collecting our database of ultrasound findings, we prepared a review of ultrasound findings mimicking the lung point sign and ultrasound variants of the true lung point sign. Results. We present four imitations of the lung point sign (physiological lung point sign, pseudo-lung point sign, bleb point sign, and pleurofascial point sign) and two variants of the true lung point sign (double lung point sign and hydro point sign) documented by images and video records. Conclusions. Knowledge of ultrasound imitations and variants of the lung point sign may increase the reliability of pneumothorax diagnosis and may reduce the risk of performing unindicated interventions.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
30223 - Anaesthesiology
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2021
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Emergency Medicine International
ISSN
2090-2840
e-ISSN
—
Svazek periodika
2021
Číslo periodika v rámci svazku
MAY
Stát vydavatele periodika
EG - Egyptská arabská republika
Počet stran výsledku
7
Strana od-do
6897946
Kód UT WoS článku
000662707400001
EID výsledku v databázi Scopus
—