Subcostal TAPSE measured by anatomical M-mode: prospective reliability clinical study in critically ill patients
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216208%3A11150%2F21%3A10435204" target="_blank" >RIV/00216208:11150/21:10435204 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/44555601:13450/21:43896810 RIV/00179906:_____/21:10435204
Výsledek na webu
<a href="https://verso.is.cuni.cz/pub/verso.fpl?fname=obd_publikace_handle&handle=ROEg-dUOhn" target="_blank" >https://verso.is.cuni.cz/pub/verso.fpl?fname=obd_publikace_handle&handle=ROEg-dUOhn</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.23736/S0375-9393.21.15464-1" target="_blank" >10.23736/S0375-9393.21.15464-1</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Subcostal TAPSE measured by anatomical M-mode: prospective reliability clinical study in critically ill patients
Popis výsledku v původním jazyce
BACKGROUND. Tricuspid annular plane systolic excursion (TAPSE), evaluated from a four-chamber apical view, is an echocardiographic parameter for the detection of right ventricular systolic dysfunction (RVD). We decided to assess the reliability of TAPSE measured from subcostal view (sTAPSE) by anatomical M-mode imaging (AMM) for evaluation of right ventricular systolic function and prediction of RVD in the critically ill patients by comparison with other echocardiographic parameters. METHODS. We conducted an observational, prospective clinical study in 100 patients hospitalized in the intensive care unit. TAPSE, doppler tissue imaging-derived tricuspid lateral annular systolic velocity (DTI-S' wave), two-dimensional fraction area change (2D FAC) and DTI-right ventricular index of myocardial performance (DTI-RIMP) were measured by transthoracic echocardiography. A subcostal four-chamber view was recorded for sTAPSE measurement. For that purpose, the cursor of AMM was aligned along the direction of the tricuspid lateral annulus movement and the amplitude of the movement was measured. RESULTS. In a group of patients aged 64 +/- 16 years with a 31% prevalence of RVD we identified strong correlation between TAPSE and sTAPSE (r=0.963, P<0.001). sTAPSE correlated well with other measures of right ventricular systolic function (DTI-S' wave: r=0.765; 2D FAC: r=0.701; DTI-RIMP: r=-0.661, P<0.001, respectively). The value of sTAPSE =15 mm predicted the presence of RVD defined by TAPSE with a sensitivity of 94.7% and specificity of 100.0%. CONCLUSIONS. The sTAPSE measured by AMM in a population of critically ill patients has been found to be a reliable parameter of right ventricular systolic function and predicted RVD with high reliability.
Název v anglickém jazyce
Subcostal TAPSE measured by anatomical M-mode: prospective reliability clinical study in critically ill patients
Popis výsledku anglicky
BACKGROUND. Tricuspid annular plane systolic excursion (TAPSE), evaluated from a four-chamber apical view, is an echocardiographic parameter for the detection of right ventricular systolic dysfunction (RVD). We decided to assess the reliability of TAPSE measured from subcostal view (sTAPSE) by anatomical M-mode imaging (AMM) for evaluation of right ventricular systolic function and prediction of RVD in the critically ill patients by comparison with other echocardiographic parameters. METHODS. We conducted an observational, prospective clinical study in 100 patients hospitalized in the intensive care unit. TAPSE, doppler tissue imaging-derived tricuspid lateral annular systolic velocity (DTI-S' wave), two-dimensional fraction area change (2D FAC) and DTI-right ventricular index of myocardial performance (DTI-RIMP) were measured by transthoracic echocardiography. A subcostal four-chamber view was recorded for sTAPSE measurement. For that purpose, the cursor of AMM was aligned along the direction of the tricuspid lateral annulus movement and the amplitude of the movement was measured. RESULTS. In a group of patients aged 64 +/- 16 years with a 31% prevalence of RVD we identified strong correlation between TAPSE and sTAPSE (r=0.963, P<0.001). sTAPSE correlated well with other measures of right ventricular systolic function (DTI-S' wave: r=0.765; 2D FAC: r=0.701; DTI-RIMP: r=-0.661, P<0.001, respectively). The value of sTAPSE =15 mm predicted the presence of RVD defined by TAPSE with a sensitivity of 94.7% and specificity of 100.0%. CONCLUSIONS. The sTAPSE measured by AMM in a population of critically ill patients has been found to be a reliable parameter of right ventricular systolic function and predicted RVD with high reliability.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
30223 - Anaesthesiology
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2021
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Minerva Anestesiologica
ISSN
0375-9393
e-ISSN
—
Svazek periodika
87
Číslo periodika v rámci svazku
11
Stát vydavatele periodika
IT - Italská republika
Počet stran výsledku
9
Strana od-do
1200-1208
Kód UT WoS článku
000719337200008
EID výsledku v databázi Scopus
2-s2.0-85120079631