Evaluation of Diurnal Changes of Mental Fatigue Using a New Portable Device for Visual Cognitive Evoked Potentials
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216208%3A11150%2F23%3A10470628" target="_blank" >RIV/00216208:11150/23:10470628 - isvavai.cz</a>
Výsledek na webu
<a href="https://verso.is.cuni.cz/pub/verso.fpl?fname=obd_publikace_handle&handle=unfKDxVlwa" target="_blank" >https://verso.is.cuni.cz/pub/verso.fpl?fname=obd_publikace_handle&handle=unfKDxVlwa</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.14712/18059694.2023.16" target="_blank" >10.14712/18059694.2023.16</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Evaluation of Diurnal Changes of Mental Fatigue Using a New Portable Device for Visual Cognitive Evoked Potentials
Popis výsledku v původním jazyce
In the age homogenous group of 13 healthy volunteers, we examined visual evoked potentials (VEP) visually evoked cognitive potentials (event-related potentials - ERP) and choice reaction time (CRT) five times during the day (from 10.00 a.m. up to midnight) to verify whether there are significant changes of the measured parameters of the cortical evoked potentials and CRT which might reflect the level of the mental fatigue. The electrophysiological testing was done with the use of a new portable VEP device named "VEPpeak" enabling to perform the examination outside standard labs in almost any conditions. It was found that the latency of ERP (P300 peak time) and CRT displayed significant prolongation toward midnight while VEP latency and all amplitudes did not change significantly. This pilot study supports our idea that the portable VEP device possibly might be used for the objective examination of mental fatigue that is needed in many situations. This should be confirmed in a larger study also including a comparison with non-electrophysiological fatigue testing.
Název v anglickém jazyce
Evaluation of Diurnal Changes of Mental Fatigue Using a New Portable Device for Visual Cognitive Evoked Potentials
Popis výsledku anglicky
In the age homogenous group of 13 healthy volunteers, we examined visual evoked potentials (VEP) visually evoked cognitive potentials (event-related potentials - ERP) and choice reaction time (CRT) five times during the day (from 10.00 a.m. up to midnight) to verify whether there are significant changes of the measured parameters of the cortical evoked potentials and CRT which might reflect the level of the mental fatigue. The electrophysiological testing was done with the use of a new portable VEP device named "VEPpeak" enabling to perform the examination outside standard labs in almost any conditions. It was found that the latency of ERP (P300 peak time) and CRT displayed significant prolongation toward midnight while VEP latency and all amplitudes did not change significantly. This pilot study supports our idea that the portable VEP device possibly might be used for the objective examination of mental fatigue that is needed in many situations. This should be confirmed in a larger study also including a comparison with non-electrophysiological fatigue testing.
Klasifikace
Druh
J<sub>SC</sub> - Článek v periodiku v databázi SCOPUS
CEP obor
—
OECD FORD obor
30103 - Neurosciences (including psychophysiology)
Návaznosti výsledku
Projekt
<a href="/cs/project/NV18-08-00314" target="_blank" >NV18-08-00314: Ověření diagnostických možností nového mobilního přístroje k vyšetřování zrakových evokovaných potenciálů</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2023
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Acta Medica (Hradec Králové)
ISSN
1211-4286
e-ISSN
1805-9694
Svazek periodika
66
Číslo periodika v rámci svazku
2
Stát vydavatele periodika
CZ - Česká republika
Počet stran výsledku
6
Strana od-do
55-60
Kód UT WoS článku
—
EID výsledku v databázi Scopus
2-s2.0-85176368264