Optimisation of an HPLC method for the simultaneous determination of pyrantel pamoate, praziquantel, fenbendazole, oxfendazole and butylhydroxyanisole using a phenyl stationary phase
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216208%3A11160%2F12%3A10124375" target="_blank" >RIV/00216208:11160/12:10124375 - isvavai.cz</a>
Výsledek na webu
<a href="http://pubs.rsc.org/en/content/articlepdf/2012/ay/c2ay05847b" target="_blank" >http://pubs.rsc.org/en/content/articlepdf/2012/ay/c2ay05847b</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1039/c2ay05847b" target="_blank" >10.1039/c2ay05847b</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Optimisation of an HPLC method for the simultaneous determination of pyrantel pamoate, praziquantel, fenbendazole, oxfendazole and butylhydroxyanisole using a phenyl stationary phase
Popis výsledku v původním jazyce
A novel and simple isocratic reversed phase HPLC method with UV and fluorimetric detection for the simultaneous determination of the active anthelmintic components pyrantel pamoate, praziquantel, fenbendazole, its degradation product oxfendazole, and theantioxidant butylhydroxyanisole (BHA) has been developed and validated. The chromatography was performed using a Phenomenex Luna 3 mm phenyl-hexyl column (150 x 3.0 mm), and the mobile phase was composed of 0.5% triethylamine at pH 9.0 and acetonitrile55 : 45 (v/v) at a flow rate of 1.0 ml min(-1). The UV detection was performed at 290 nm for pyrantel, oxfendazole and fenbendazole and at 220 nm for praziquantel. For BHA, fluorescence detection was used with excitation and emission wavelengths of 287 nm and 322 nm, respectively. The method was validated and was applied for the determination of active compounds in various dosage forms of veterinary formulations.
Název v anglickém jazyce
Optimisation of an HPLC method for the simultaneous determination of pyrantel pamoate, praziquantel, fenbendazole, oxfendazole and butylhydroxyanisole using a phenyl stationary phase
Popis výsledku anglicky
A novel and simple isocratic reversed phase HPLC method with UV and fluorimetric detection for the simultaneous determination of the active anthelmintic components pyrantel pamoate, praziquantel, fenbendazole, its degradation product oxfendazole, and theantioxidant butylhydroxyanisole (BHA) has been developed and validated. The chromatography was performed using a Phenomenex Luna 3 mm phenyl-hexyl column (150 x 3.0 mm), and the mobile phase was composed of 0.5% triethylamine at pH 9.0 and acetonitrile55 : 45 (v/v) at a flow rate of 1.0 ml min(-1). The UV detection was performed at 290 nm for pyrantel, oxfendazole and fenbendazole and at 220 nm for praziquantel. For BHA, fluorescence detection was used with excitation and emission wavelengths of 287 nm and 322 nm, respectively. The method was validated and was applied for the determination of active compounds in various dosage forms of veterinary formulations.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
CB - Analytická chemie, separace
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach<br>I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2012
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Analytical Methods
ISSN
1759-9660
e-ISSN
—
Svazek periodika
4
Číslo periodika v rámci svazku
6
Stát vydavatele periodika
GB - Spojené království Velké Británie a Severního Irska
Počet stran výsledku
6
Strana od-do
1592-1597
Kód UT WoS článku
000304768600020
EID výsledku v databázi Scopus
—