Highly sensitive sequential injection determination of p-aminophenol in paracetamol formulations with 18-molybdodiphosphate heteropoly anion based on elimination of Schlieren effect
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216208%3A11160%2F12%3A10124674" target="_blank" >RIV/00216208:11160/12:10124674 - isvavai.cz</a>
Výsledek na webu
<a href="http://www.sciencedirect.com/science/article/pii/S0039914012001877" target="_blank" >http://www.sciencedirect.com/science/article/pii/S0039914012001877</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.talanta.2012.02.049" target="_blank" >10.1016/j.talanta.2012.02.049</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Highly sensitive sequential injection determination of p-aminophenol in paracetamol formulations with 18-molybdodiphosphate heteropoly anion based on elimination of Schlieren effect
Popis výsledku v původním jazyce
A highly sensitive, precise and automated method using sequential injection analysis to assay quantitatively low levels of the p-aminophenol (PAP) in paracetamol formulations has been developed. A solution containing PAP and paracetamol is injected intoan acetate buffer carrier stream and merged on-line with 18-molybdodiphosphate heteropoly complex reagent to form a specific blue derivative that is subsequently detected spectrophotometrically at 820 nm. The procedure has been optimized mainly with respect to measurement sensitivity. It is based on the leveling off of the refraction indices of the liquids mixed in the flow system by the careful matching of the refractive index of the reagent solution with that of the carrier and sample solutions. Amount as low as 0.5 mu mol L-1 of PAP, which corresponds to the 0.001% of PAP in paracetamol tablets, can be reliably determined using the proposed method, which is clearly below the specification limits recommended for PAP determination in p
Název v anglickém jazyce
Highly sensitive sequential injection determination of p-aminophenol in paracetamol formulations with 18-molybdodiphosphate heteropoly anion based on elimination of Schlieren effect
Popis výsledku anglicky
A highly sensitive, precise and automated method using sequential injection analysis to assay quantitatively low levels of the p-aminophenol (PAP) in paracetamol formulations has been developed. A solution containing PAP and paracetamol is injected intoan acetate buffer carrier stream and merged on-line with 18-molybdodiphosphate heteropoly complex reagent to form a specific blue derivative that is subsequently detected spectrophotometrically at 820 nm. The procedure has been optimized mainly with respect to measurement sensitivity. It is based on the leveling off of the refraction indices of the liquids mixed in the flow system by the careful matching of the refractive index of the reagent solution with that of the carrier and sample solutions. Amount as low as 0.5 mu mol L-1 of PAP, which corresponds to the 0.001% of PAP in paracetamol tablets, can be reliably determined using the proposed method, which is clearly below the specification limits recommended for PAP determination in p
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
CB - Analytická chemie, separace
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)<br>I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2012
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Talanta
ISSN
0039-9140
e-ISSN
—
Svazek periodika
96
Číslo periodika v rámci svazku
1
Stát vydavatele periodika
NL - Nizozemsko
Počet stran výsledku
6
Strana od-do
230-235
Kód UT WoS článku
000307419700037
EID výsledku v databázi Scopus
—