A miniaturized analyzer for the catalytic determination of iodide in seawater and pharmaceutical samples
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216208%3A11160%2F13%3A10145758" target="_blank" >RIV/00216208:11160/13:10145758 - isvavai.cz</a>
Výsledek na webu
<a href="http://www.sciencedirect.com/science/article/pii/S003991401300146X" target="_blank" >http://www.sciencedirect.com/science/article/pii/S003991401300146X</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.talanta.2013.02.072" target="_blank" >10.1016/j.talanta.2013.02.072</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
A miniaturized analyzer for the catalytic determination of iodide in seawater and pharmaceutical samples
Popis výsledku v původním jazyce
A monolithic flow conduit was especially designed and coupled to a multisyringe unit (MSFIA) in order to develop a kinetic analytical method. The new device, denoted CHIP, integrates different functions in a reduced size including confluent mixing, reaction coil, and thermostating, which allowed minimizing the dimensions of the entire analyzer system. The CHIP-MSFIA was satisfactorily applied to the determination of iodide using the Sandell-Kolthoff reaction. The resulting system allows fast, simple andautomatic analysis in seawater samples and a pharmaceutical preparation. By the use of an additional syringe, reagent blank, sample blank, unspecific interferences, and sample analyte concentration was evaluated by simply changing the mode of operation.The instrumentation and analytical procedures were optimized in respect of sensitivity. A limit of detection of 4.7 mu g L-1 and linear working range of 4.3-70 mu g L-1 were achieved. Two new modes of air bubble elimination were develope
Název v anglickém jazyce
A miniaturized analyzer for the catalytic determination of iodide in seawater and pharmaceutical samples
Popis výsledku anglicky
A monolithic flow conduit was especially designed and coupled to a multisyringe unit (MSFIA) in order to develop a kinetic analytical method. The new device, denoted CHIP, integrates different functions in a reduced size including confluent mixing, reaction coil, and thermostating, which allowed minimizing the dimensions of the entire analyzer system. The CHIP-MSFIA was satisfactorily applied to the determination of iodide using the Sandell-Kolthoff reaction. The resulting system allows fast, simple andautomatic analysis in seawater samples and a pharmaceutical preparation. By the use of an additional syringe, reagent blank, sample blank, unspecific interferences, and sample analyte concentration was evaluated by simply changing the mode of operation.The instrumentation and analytical procedures were optimized in respect of sensitivity. A limit of detection of 4.7 mu g L-1 and linear working range of 4.3-70 mu g L-1 were achieved. Two new modes of air bubble elimination were develope
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
CB - Analytická chemie, separace
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/EE2.3.30.0022" target="_blank" >EE2.3.30.0022: Podpora vytváření, rozvoje a mobility kvalitních výzkumně-vývojových týmů na Univerzitě Karlově</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2013
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Talanta
ISSN
0039-9140
e-ISSN
—
Svazek periodika
108
Číslo periodika v rámci svazku
April
Stát vydavatele periodika
NL - Nizozemsko
Počet stran výsledku
11
Strana od-do
92-102
Kód UT WoS článku
000319088900014
EID výsledku v databázi Scopus
—