Development and validation of ultra-high performance supercritical fluid chromatography method for quantitative determination of nine sunscreens in cosmetic samples
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216208%3A11160%2F18%3A10383072" target="_blank" >RIV/00216208:11160/18:10383072 - isvavai.cz</a>
Výsledek na webu
<a href="http://www.sciencedirect.com/science/article/pii/S000326701830775X" target="_blank" >http://www.sciencedirect.com/science/article/pii/S000326701830775X</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.aca.2018.06.013" target="_blank" >10.1016/j.aca.2018.06.013</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Development and validation of ultra-high performance supercritical fluid chromatography method for quantitative determination of nine sunscreens in cosmetic samples
Popis výsledku v původním jazyce
A fast and simple utra-high performance supercritical fluid chromatography (UHPSFC) method has been developed for the determination of nine sunscreens (UV filters), namely 2-ethylhexyl-2-hydroxybenzoate (ES), ethylhexyl-methoxycinnamate (EMC), benzophenone-3 (BZ3), octocrylene (OCR), bis-ethylhexyloxyphenol-methoxyphenyl triazine (EMT), butyl-methoxydibenzoyl-methane (BDM), diethylamino-hydroxybenzoyl-hexyl-benzoate (DHB), ethylhexyl-triazone (ET), and diethylhexyl-butamido-triazone (DBT) in cosmetic samples. The separation was achieved with Acquity UPC2 Torus 2-PIC (100 x 3.0 mm, 1.7 mu m) column. The influence of key chromatographic parameters on resolution was evaluated. The optimal mobile phase was a gradient mixture of carbon dioxide and methanol containing ammonium acetate, at flow rate 1.2 mL min(-1). The back-pressure of the system was set to 150 bar and the temperature to 40 degrees C. The compounds were determined with diode-array detection at 280 nm, 305 nm and 340 nm depending on absorbance maxima. The proposed UHPSFC method provided separation of the nine target sunscreens within 2.5 min without labor-consuming sample pretreatment procedure. The method was validated according to the concept of the total error and the accuracy profile. The inter-laboratory reproducibility was evaluated between two independent laboratories (in France and Czech Republic). The reliability of the developed method was shown by application to commercial sunscreen-containing cosmetic sample obtained from French market. The measured limits of quantification showed the suitability of the proposed method for determination of UV filters considering the European Union requirements. (C) 2018 Elsevier B.V. All rights reserved.
Název v anglickém jazyce
Development and validation of ultra-high performance supercritical fluid chromatography method for quantitative determination of nine sunscreens in cosmetic samples
Popis výsledku anglicky
A fast and simple utra-high performance supercritical fluid chromatography (UHPSFC) method has been developed for the determination of nine sunscreens (UV filters), namely 2-ethylhexyl-2-hydroxybenzoate (ES), ethylhexyl-methoxycinnamate (EMC), benzophenone-3 (BZ3), octocrylene (OCR), bis-ethylhexyloxyphenol-methoxyphenyl triazine (EMT), butyl-methoxydibenzoyl-methane (BDM), diethylamino-hydroxybenzoyl-hexyl-benzoate (DHB), ethylhexyl-triazone (ET), and diethylhexyl-butamido-triazone (DBT) in cosmetic samples. The separation was achieved with Acquity UPC2 Torus 2-PIC (100 x 3.0 mm, 1.7 mu m) column. The influence of key chromatographic parameters on resolution was evaluated. The optimal mobile phase was a gradient mixture of carbon dioxide and methanol containing ammonium acetate, at flow rate 1.2 mL min(-1). The back-pressure of the system was set to 150 bar and the temperature to 40 degrees C. The compounds were determined with diode-array detection at 280 nm, 305 nm and 340 nm depending on absorbance maxima. The proposed UHPSFC method provided separation of the nine target sunscreens within 2.5 min without labor-consuming sample pretreatment procedure. The method was validated according to the concept of the total error and the accuracy profile. The inter-laboratory reproducibility was evaluated between two independent laboratories (in France and Czech Republic). The reliability of the developed method was shown by application to commercial sunscreen-containing cosmetic sample obtained from French market. The measured limits of quantification showed the suitability of the proposed method for determination of UV filters considering the European Union requirements. (C) 2018 Elsevier B.V. All rights reserved.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
10406 - Analytical chemistry
Návaznosti výsledku
Projekt
<a href="/cs/project/EF15_003%2F0000465" target="_blank" >EF15_003/0000465: Vytvoření expertního týmu pro pokročilý výzkum v separačních vědách</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>S - Specificky vyzkum na vysokych skolach<br>I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2018
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Analytica Chimica Acta
ISSN
0003-2670
e-ISSN
—
Svazek periodika
1034
Číslo periodika v rámci svazku
November
Stát vydavatele periodika
NL - Nizozemsko
Počet stran výsledku
11
Strana od-do
184-194
Kód UT WoS článku
000443565500020
EID výsledku v databázi Scopus
2-s2.0-85048300564