Supercritical fluid chromatography in chiral separations: Evaluation of equivalency of polysaccharide stationary phases
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216208%3A11160%2F20%3A10418021" target="_blank" >RIV/00216208:11160/20:10418021 - isvavai.cz</a>
Výsledek na webu
<a href="https://verso.is.cuni.cz/pub/verso.fpl?fname=obd_publikace_handle&handle=qts~1bVEzn" target="_blank" >https://verso.is.cuni.cz/pub/verso.fpl?fname=obd_publikace_handle&handle=qts~1bVEzn</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1002/jssc.202000085" target="_blank" >10.1002/jssc.202000085</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Supercritical fluid chromatography in chiral separations: Evaluation of equivalency of polysaccharide stationary phases
Popis výsledku v původním jazyce
Nine different chiral columns based on covalently immobilized or coated tris(3,5-dimethylphenylcarbamate) cellulose and amylose have been explored. We evaluated their respective enantioselective potential including the enantioseparation and qualitative characteristics of peaks. The generic screening conditions were using gradient elution from 5 to 40% organic modifier/CO2 during 3 min with about 40 enantiomer pairs. Primary screening was carried out using ten different mobile phases varying in type of additives while using one representative amylose- and one cellulose-based column. The complete evaluation of all nine columns was then carried out using three best performing organic modifiers: (1) methanol + 0.1% trifluoroacetic acid + 0.1% diethylamine, (2) isopropanol + 0.1% trifluoroacetic acid + 0.1% diethylamine, and (3) methanol + 0.1% ammonium hydroxide. Equivalency of different columns with the same chiral selector was not confirmed. Columns with the same stationary phase but different supports or manufacturing methods displayed differences in enantioselectivity and general performance. The similarity corresponded to 62 and 63% for the three cellulose-coated columns taking CEL1 as the reference. The similarity was 67% for the pair of amylose-based coated columns. For immobilized columns, the similarity was 69 and 59% for celluloses and amyloses pairs, respectively. The best performing column based on success rate of enantioseparation was Chiralcel OD-3 when using methanol + 0.1% trifluoroacetic acid and 0.1% diethylamine combined additive.
Název v anglickém jazyce
Supercritical fluid chromatography in chiral separations: Evaluation of equivalency of polysaccharide stationary phases
Popis výsledku anglicky
Nine different chiral columns based on covalently immobilized or coated tris(3,5-dimethylphenylcarbamate) cellulose and amylose have been explored. We evaluated their respective enantioselective potential including the enantioseparation and qualitative characteristics of peaks. The generic screening conditions were using gradient elution from 5 to 40% organic modifier/CO2 during 3 min with about 40 enantiomer pairs. Primary screening was carried out using ten different mobile phases varying in type of additives while using one representative amylose- and one cellulose-based column. The complete evaluation of all nine columns was then carried out using three best performing organic modifiers: (1) methanol + 0.1% trifluoroacetic acid + 0.1% diethylamine, (2) isopropanol + 0.1% trifluoroacetic acid + 0.1% diethylamine, and (3) methanol + 0.1% ammonium hydroxide. Equivalency of different columns with the same chiral selector was not confirmed. Columns with the same stationary phase but different supports or manufacturing methods displayed differences in enantioselectivity and general performance. The similarity corresponded to 62 and 63% for the three cellulose-coated columns taking CEL1 as the reference. The similarity was 67% for the pair of amylose-based coated columns. For immobilized columns, the similarity was 69 and 59% for celluloses and amyloses pairs, respectively. The best performing column based on success rate of enantioseparation was Chiralcel OD-3 when using methanol + 0.1% trifluoroacetic acid and 0.1% diethylamine combined additive.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
30104 - Pharmacology and pharmacy
Návaznosti výsledku
Projekt
<a href="/cs/project/EF15_003%2F0000465" target="_blank" >EF15_003/0000465: Vytvoření expertního týmu pro pokročilý výzkum v separačních vědách</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>S - Specificky vyzkum na vysokych skolach<br>I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2020
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Journal of Separation Science
ISSN
1615-9306
e-ISSN
—
Svazek periodika
43
Číslo periodika v rámci svazku
13
Stát vydavatele periodika
DE - Spolková republika Německo
Počet stran výsledku
15
Strana od-do
2675-2689
Kód UT WoS článku
000538741300001
EID výsledku v databázi Scopus
2-s2.0-85086050384