Ion mobility-high resolution mass spectrometry in anti-doping analysis. Part I: Implementation of a screening method with the assessment of a library of substances prohibited in sports
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216208%3A11160%2F21%3A10434516" target="_blank" >RIV/00216208:11160/21:10434516 - isvavai.cz</a>
Výsledek na webu
<a href="https://verso.is.cuni.cz/pub/verso.fpl?fname=obd_publikace_handle&handle=M0bpYSOV0F" target="_blank" >https://verso.is.cuni.cz/pub/verso.fpl?fname=obd_publikace_handle&handle=M0bpYSOV0F</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.aca.2021.338257" target="_blank" >10.1016/j.aca.2021.338257</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Ion mobility-high resolution mass spectrometry in anti-doping analysis. Part I: Implementation of a screening method with the assessment of a library of substances prohibited in sports
Popis výsledku v původním jazyce
In this series of two papers, 192 doping agents belonging to the classes of stimulants, narcotics, cannabinoids, diuretics, beta 2-agonists, beta-blockers, anabolic agents, and hormone and metabolic modulators were investigated, with the aim to assess the benefits and limitations of ion mobility spectrometry (IMS) in combination with ultra-high performance liquid chromatography (UHPLC) and high resolution mass spectrometry (HRMS) in anti-doping analysis. In this first part, a generic UHPLC-IM-HRMS method was successfully developed to analyze these 192 doping agents in standard solutions and urine samples, and an exhaustive database including retention times, (CCSN2)-C-TW values, and m/z ratios was constructed. Urine samples were analyzed using either a simple "dilute and shoot" procedure or a supported liquid-liquid extraction (SLE) procedure, depending on the physicochemical properties of the compounds and sensitivity criteria established by the World Anti-Doping Agency (WADA) as the minimum required performance levels (MRPL). Then, the precision of the generic UHPLC-IM-HRMS method was assessed as intraday, interday as well as interweek variation of UHPLC retention times and (CCSN2)-C-TW values, for which RSD the values were always lower than 2% in urine samples. The possibility to filter MS data using IMS dimension was also investigated, and in average, the application of IMS filtration provided low energy MS spectra with 86% less interfering peaks in both standard and urine samples. Therefore, the filtered MS spectra allowed for an easier interpretation and a lower risk of false positive result interpretations. Finally, IMS also offers additional selectivity to the UHPLC-HRMS enabling to separate isobaric and isomeric substances. Among the selected set of 192 doping agents, there were 30 pairs of isobaric or isomeric compounds, and only two pairs could not be resolved under the developed conditions. This illustrates the potential of adding ion mobility to UHPLCHRMS in anti-doping analyses.
Název v anglickém jazyce
Ion mobility-high resolution mass spectrometry in anti-doping analysis. Part I: Implementation of a screening method with the assessment of a library of substances prohibited in sports
Popis výsledku anglicky
In this series of two papers, 192 doping agents belonging to the classes of stimulants, narcotics, cannabinoids, diuretics, beta 2-agonists, beta-blockers, anabolic agents, and hormone and metabolic modulators were investigated, with the aim to assess the benefits and limitations of ion mobility spectrometry (IMS) in combination with ultra-high performance liquid chromatography (UHPLC) and high resolution mass spectrometry (HRMS) in anti-doping analysis. In this first part, a generic UHPLC-IM-HRMS method was successfully developed to analyze these 192 doping agents in standard solutions and urine samples, and an exhaustive database including retention times, (CCSN2)-C-TW values, and m/z ratios was constructed. Urine samples were analyzed using either a simple "dilute and shoot" procedure or a supported liquid-liquid extraction (SLE) procedure, depending on the physicochemical properties of the compounds and sensitivity criteria established by the World Anti-Doping Agency (WADA) as the minimum required performance levels (MRPL). Then, the precision of the generic UHPLC-IM-HRMS method was assessed as intraday, interday as well as interweek variation of UHPLC retention times and (CCSN2)-C-TW values, for which RSD the values were always lower than 2% in urine samples. The possibility to filter MS data using IMS dimension was also investigated, and in average, the application of IMS filtration provided low energy MS spectra with 86% less interfering peaks in both standard and urine samples. Therefore, the filtered MS spectra allowed for an easier interpretation and a lower risk of false positive result interpretations. Finally, IMS also offers additional selectivity to the UHPLC-HRMS enabling to separate isobaric and isomeric substances. Among the selected set of 192 doping agents, there were 30 pairs of isobaric or isomeric compounds, and only two pairs could not be resolved under the developed conditions. This illustrates the potential of adding ion mobility to UHPLCHRMS in anti-doping analyses.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
30104 - Pharmacology and pharmacy
Návaznosti výsledku
Projekt
<a href="/cs/project/EF15_003%2F0000465" target="_blank" >EF15_003/0000465: Vytvoření expertního týmu pro pokročilý výzkum v separačních vědách</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>S - Specificky vyzkum na vysokych skolach<br>I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2021
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Analytica Chimica Acta
ISSN
0003-2670
e-ISSN
—
Svazek periodika
1152
Číslo periodika v rámci svazku
April
Stát vydavatele periodika
NL - Nizozemsko
Počet stran výsledku
16
Strana od-do
338257
Kód UT WoS článku
000626407900009
EID výsledku v databázi Scopus
2-s2.0-85100508272