Popis výsledku v původním jazyce
The effective gait restoration due to antigravity treadmill exercise has been demonstrated in patients with locomotor or nervous system disorders. The element of unweighting, its effect on the parameters of the gait cycle and possible deviation from overground walking, despite all the clinical evidence, remains questionable. A retrospective analysis of 405 therapy records of patients recovering after lower limb surgery focused on the dependence between body-weight supported treadmill settings (speed, unweighting) and gait cycle parameters (cadence, stance time, step time, swing time, step length and stride length) together with their symmetry indexes.The relationship between therapy settings and respective gait parameters and their symmetry indexes has been evaluated by Pearson correlation coefficient. While a significant relationship between speed and all analyzed gait parameters, except of swing time of unaffected limb, has been found, no significant impact of unweighting has been proven on any of the gait parameters. The symmetry index turned out to be a suitable tool for monitoring the state of recovery, as no dependence on speed or unweighting settings was proven. The results of this study show that walking on an antigravity treadmill, similarly to overground walking, has no negative effect on walking parameters. In addition, the unweighting element enables performing the same movement with a lower load on the lower extremities and thus might be more suitable for gait recovery after surgery or injury of the locomotor system.
Název v anglickém jazyce
The Relationship between Antigravity Treadmill Therapy Settings and Gait Cycle Parameters
Popis výsledku anglicky
The effective gait restoration due to antigravity treadmill exercise has been demonstrated in patients with locomotor or nervous system disorders. The element of unweighting, its effect on the parameters of the gait cycle and possible deviation from overground walking, despite all the clinical evidence, remains questionable. A retrospective analysis of 405 therapy records of patients recovering after lower limb surgery focused on the dependence between body-weight supported treadmill settings (speed, unweighting) and gait cycle parameters (cadence, stance time, step time, swing time, step length and stride length) together with their symmetry indexes.The relationship between therapy settings and respective gait parameters and their symmetry indexes has been evaluated by Pearson correlation coefficient. While a significant relationship between speed and all analyzed gait parameters, except of swing time of unaffected limb, has been found, no significant impact of unweighting has been proven on any of the gait parameters. The symmetry index turned out to be a suitable tool for monitoring the state of recovery, as no dependence on speed or unweighting settings was proven. The results of this study show that walking on an antigravity treadmill, similarly to overground walking, has no negative effect on walking parameters. In addition, the unweighting element enables performing the same movement with a lower load on the lower extremities and thus might be more suitable for gait recovery after surgery or injury of the locomotor system.
Klasifikace
Druh
J<sub>ost</sub> - Ostatní články v recenzovaných periodicích
CEP obor
—
OECD FORD obor
30306 - Sport and fitness sciences
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2023
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Journal of Orthopaedics and Sports Medicine
ISSN
2688-5115
e-ISSN
2688-5115
Svazek periodika
5
Číslo periodika v rámci svazku
4
Stát vydavatele periodika
US - Spojené státy americké
Počet stran výsledku
10
Strana od-do
406-415
Kód UT WoS článku
—
EID výsledku v databázi Scopus
—