Voltammetric Determination of 4-Nitrophenol Using Novel Type of Silver Amalgam Paste Electrode
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216208%3A11310%2F09%3A00012668" target="_blank" >RIV/00216208:11310/09:00012668 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Voltammetric Determination of 4-Nitrophenol Using Novel Type of Silver Amalgam Paste Electrode
Popis výsledku v původním jazyce
A differential pulse voltammetric (DPV) method was developed for the determination of 4-nitrophenol (4-NP) at a newly developed silver amalgam paste electrode (AgA-PE) in Britton-Robinson buffer pH 3.0. The electrode is based on a disposable plastic pipette tip filled with paste amalgam based on a mixture of mercury and fine silver powder (9:1, w/w). The experimental parameters, such as pH of Britton-Robinson buffer and activation and regeneration potential of the electrode surface were optimized. The reduction peak current dependences were linear for the concentration of 4-NP from 0.2 to 100 ?M. The method showed reproducible results with RSD (n = 45) of 1.7%. The limit of determination (LOD) was 0.3 ?M. The method was successfully applied for the direct determination of 4-NP in drinking water.
Název v anglickém jazyce
Voltammetric Determination of 4-Nitrophenol Using Novel Type of Silver Amalgam Paste Electrode
Popis výsledku anglicky
A differential pulse voltammetric (DPV) method was developed for the determination of 4-nitrophenol (4-NP) at a newly developed silver amalgam paste electrode (AgA-PE) in Britton-Robinson buffer pH 3.0. The electrode is based on a disposable plastic pipette tip filled with paste amalgam based on a mixture of mercury and fine silver powder (9:1, w/w). The experimental parameters, such as pH of Britton-Robinson buffer and activation and regeneration potential of the electrode surface were optimized. The reduction peak current dependences were linear for the concentration of 4-NP from 0.2 to 100 ?M. The method showed reproducible results with RSD (n = 45) of 1.7%. The limit of determination (LOD) was 0.3 ?M. The method was successfully applied for the direct determination of 4-NP in drinking water.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
CG - Elektrochemie
OECD FORD obor
—
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2009
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Electroanalysis
ISSN
1040-0397
e-ISSN
—
Svazek periodika
21
Číslo periodika v rámci svazku
16
Stát vydavatele periodika
DE - Spolková republika Německo
Počet stran výsledku
6
Strana od-do
—
Kód UT WoS článku
000269425100003
EID výsledku v databázi Scopus
—