Anodic Stripping Voltammetry Using Graphite Composite Solid Electrode
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216208%3A11310%2F09%3A10001205" target="_blank" >RIV/00216208:11310/09:10001205 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/61388955:_____/09:00338295
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Anodic Stripping Voltammetry Using Graphite Composite Solid Electrode
Popis výsledku v původním jazyce
A graphite composite solid electrode (CCE), prepared from graphite powder and epoxy resin, was used as a working electrode for anodic stripping voltammetry. The underpotential deposition effect, which appears at metallic electrodes, was clearly observedon this type of electrode as well. In the case of a simultaneous deposition of two metals on the surface of the composite solid electrode (CSE), the anodic dissolution of the metal, which is anodically dissolved at more negative potential, is substantially influenced by the presence of the other deposited metal. This effect was exploited for the determination of lead in the presence of other metals by differential pulse anodic stripping voltammetry. The article presents the possible applicability of such a type of very simple composite electrode for the studies of underpotential deposition effect as well as for analytical purposes.
Název v anglickém jazyce
Anodic Stripping Voltammetry Using Graphite Composite Solid Electrode
Popis výsledku anglicky
A graphite composite solid electrode (CCE), prepared from graphite powder and epoxy resin, was used as a working electrode for anodic stripping voltammetry. The underpotential deposition effect, which appears at metallic electrodes, was clearly observedon this type of electrode as well. In the case of a simultaneous deposition of two metals on the surface of the composite solid electrode (CSE), the anodic dissolution of the metal, which is anodically dissolved at more negative potential, is substantially influenced by the presence of the other deposited metal. This effect was exploited for the determination of lead in the presence of other metals by differential pulse anodic stripping voltammetry. The article presents the possible applicability of such a type of very simple composite electrode for the studies of underpotential deposition effect as well as for analytical purposes.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
CG - Elektrochemie
OECD FORD obor
—
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2009
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Collection of Czechoslovak Chemical Communications
ISSN
0010-0765
e-ISSN
—
Svazek periodika
74
Číslo periodika v rámci svazku
11-12
Stát vydavatele periodika
CZ - Česká republika
Počet stran výsledku
20
Strana od-do
—
Kód UT WoS článku
—
EID výsledku v databázi Scopus
—