Voltammetric and Amperometric Determination of N-Nitroso Antineoplastic Drugs at Mercury and Amalgam Electrodes
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216208%3A11310%2F09%3A10001348" target="_blank" >RIV/00216208:11310/09:10001348 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Voltammetric and Amperometric Determination of N-Nitroso Antineoplastic Drugs at Mercury and Amalgam Electrodes
Popis výsledku v původním jazyce
Hanging mercury drop electrode and mercury meniscus modified silver solid amalgam electrode were used as electroanalytical sensors for voltammetric determination of antineoplastic drugs carmustine, lomustine and streptozotocin containing reducible N-nitroso group. On the example of carmustine it was shown that the one-step reduction occurs at substantially more negative potentials at amalgam electrode as compared with mercury electrode. Both electrodes offer satisfactory repeatability of current response (relative standard deviations < 5 %) using DC voltammetry and differential pulse voltammetry. Achieved limits of determination lie mostly in the 10?7 mol l?1 concentration range. Further, the mercury meniscus modified silver solid amalgam electrode wasemployed in ?wall-jet? amperometric detection cell for determination of carmustine in flow injection analysis.
Název v anglickém jazyce
Voltammetric and Amperometric Determination of N-Nitroso Antineoplastic Drugs at Mercury and Amalgam Electrodes
Popis výsledku anglicky
Hanging mercury drop electrode and mercury meniscus modified silver solid amalgam electrode were used as electroanalytical sensors for voltammetric determination of antineoplastic drugs carmustine, lomustine and streptozotocin containing reducible N-nitroso group. On the example of carmustine it was shown that the one-step reduction occurs at substantially more negative potentials at amalgam electrode as compared with mercury electrode. Both electrodes offer satisfactory repeatability of current response (relative standard deviations < 5 %) using DC voltammetry and differential pulse voltammetry. Achieved limits of determination lie mostly in the 10?7 mol l?1 concentration range. Further, the mercury meniscus modified silver solid amalgam electrode wasemployed in ?wall-jet? amperometric detection cell for determination of carmustine in flow injection analysis.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
CG - Elektrochemie
OECD FORD obor
—
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2009
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Collection of Czechoslovak Chemical Communications
ISSN
0010-0765
e-ISSN
—
Svazek periodika
74
Číslo periodika v rámci svazku
11-12
Stát vydavatele periodika
CZ - Česká republika
Počet stran výsledku
17
Strana od-do
—
Kód UT WoS článku
—
EID výsledku v databázi Scopus
—