Polarographic and Voltammetric Determination of Genotoxic 9-Fluorenone and its Derivatives
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216208%3A11310%2F11%3A10105118" target="_blank" >RIV/00216208:11310/11:10105118 - isvavai.cz</a>
Výsledek na webu
<a href="http://www.bestservis.eu/Rakce/lang" target="_blank" >http://www.bestservis.eu/Rakce/lang</a>
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Polarographic and Voltammetric Determination of Genotoxic 9-Fluorenone and its Derivatives
Popis výsledku v původním jazyce
Polarographic and voltammetric behavior of genotoxic 9-fluorenone (FN) and its genotoxic derivatives, namely 2-nitro-9-fluorenone (2-NFN), 2,7-dinitro-9-fluorenone (2,7-DNFN), and 2-amino-9-fluorenone (2-AFN), has been investigated at a dropping mercuryelectrode (DME), a hanging mercury drop electrode (HMDE), and a mercury meniscus modified silver solid amalgam electrode (m-AgSAE). The optimum conditions have been investigated in methanolic-aqueous media buffered using Britton-Robinson buffer. Under optimum conditions, linear calibration curves were measured with nanomolar to micromolar limits of quantification reached. These newly developed polarographic and voltammetric methods have been successfully applied to model samples of drinking and river water spiked with determined substances.
Název v anglickém jazyce
Polarographic and Voltammetric Determination of Genotoxic 9-Fluorenone and its Derivatives
Popis výsledku anglicky
Polarographic and voltammetric behavior of genotoxic 9-fluorenone (FN) and its genotoxic derivatives, namely 2-nitro-9-fluorenone (2-NFN), 2,7-dinitro-9-fluorenone (2,7-DNFN), and 2-amino-9-fluorenone (2-AFN), has been investigated at a dropping mercuryelectrode (DME), a hanging mercury drop electrode (HMDE), and a mercury meniscus modified silver solid amalgam electrode (m-AgSAE). The optimum conditions have been investigated in methanolic-aqueous media buffered using Britton-Robinson buffer. Under optimum conditions, linear calibration curves were measured with nanomolar to micromolar limits of quantification reached. These newly developed polarographic and voltammetric methods have been successfully applied to model samples of drinking and river water spiked with determined substances.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
CG - Elektrochemie
OECD FORD obor
—
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2011
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Moderní elektrochemické metody: sborník přednášek XXXI. mezinárodní odborné konference: Jetřichovice 23. ? 27. května 2011
ISBN
978-80-254-9634-3
ISSN
—
e-ISSN
—
Počet stran výsledku
5
Strana od-do
185-189
Název nakladatele
BEST servis Ústí nad Labem
Místo vydání
Ústí nad Labem
Místo konání akce
Jetřichovice
Datum konání akce
23. 5. 2011
Typ akce podle státní příslušnosti
EUR - Evropská akce
Kód UT WoS článku
—