Relationship of indoor and outdoor air pollutants in a naturally ventilated historical building envelope
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216208%3A11310%2F11%3A10107457" target="_blank" >RIV/00216208:11310/11:10107457 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/67985858:_____/11:00359248
Výsledek na webu
<a href="http://www.sciencedirect.com/science/article/pii/S0360132311000230" target="_blank" >http://www.sciencedirect.com/science/article/pii/S0360132311000230</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.buildenv.2011.01.013" target="_blank" >10.1016/j.buildenv.2011.01.013</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Relationship of indoor and outdoor air pollutants in a naturally ventilated historical building envelope
Popis výsledku v původním jazyce
Concentrations of NO2, O3, SO2, acetic and formic acids, HNO3 and NH3 were measured inside and outside a historical building, the Baroque Library Hall (BLH) in the National Library in Prague (Czech Republic). The naturally ventilated system of the building, the restriction of personnel access, reduced groups of visitors and absence of activities which could influence indoor pollutant concentrations are characteristics that make the Baroque Library Hall a suitable location to study the influence of outdoor environment on the indoor air quality. The relationship between indoor and outdoor (I/O) concentration was investigated to assess the infiltration of outdoor generated pollutants. Outdoor and indoor pollution sources were determined and, infiltrationof ammonium nitrate and a shift of the equilibrium to the gas phase were the reason for the high concentration of ammonia measured inside the BLH. A significant seasonal variation was observed and interpreted as a consequence of different
Název v anglickém jazyce
Relationship of indoor and outdoor air pollutants in a naturally ventilated historical building envelope
Popis výsledku anglicky
Concentrations of NO2, O3, SO2, acetic and formic acids, HNO3 and NH3 were measured inside and outside a historical building, the Baroque Library Hall (BLH) in the National Library in Prague (Czech Republic). The naturally ventilated system of the building, the restriction of personnel access, reduced groups of visitors and absence of activities which could influence indoor pollutant concentrations are characteristics that make the Baroque Library Hall a suitable location to study the influence of outdoor environment on the indoor air quality. The relationship between indoor and outdoor (I/O) concentration was investigated to assess the infiltration of outdoor generated pollutants. Outdoor and indoor pollution sources were determined and, infiltrationof ammonium nitrate and a shift of the equilibrium to the gas phase were the reason for the high concentration of ammonia measured inside the BLH. A significant seasonal variation was observed and interpreted as a consequence of different
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
DI - Znečištění a kontrola vzduchu
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
O - Projekt operacniho programu
Ostatní
Rok uplatnění
2011
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Building and Environment
ISSN
0360-1323
e-ISSN
—
Svazek periodika
46
Číslo periodika v rámci svazku
7
Stát vydavatele periodika
GB - Spojené království Velké Británie a Severního Irska
Počet stran výsledku
9
Strana od-do
1460-1468
Kód UT WoS článku
000288886000013
EID výsledku v databázi Scopus
—