Comparison of LC Columns Packed with 2.6 mu m Core-Shell and Sub-2 mu m Porous Particles for Gradient Separation of Antibiotics
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216208%3A11310%2F11%3A10112536" target="_blank" >RIV/00216208:11310/11:10112536 - isvavai.cz</a>
Výsledek na webu
<a href="http://dx.doi.org/10.1007/s10337-011-2021-7" target="_blank" >http://dx.doi.org/10.1007/s10337-011-2021-7</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1007/s10337-011-2021-7" target="_blank" >10.1007/s10337-011-2021-7</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Comparison of LC Columns Packed with 2.6 mu m Core-Shell and Sub-2 mu m Porous Particles for Gradient Separation of Antibiotics
Popis výsledku v původním jazyce
The recently introduced Kinetex C18 column packed with core-shell 2.6 mu m particles is declared to provide similar efficiency and short analysis as Acquity BEH C18 column with 1.7 mu m porous particles. Unlike Acquity BEH C18 column, Kinetex C18 columnexhibited lower column backpressure making this column compatible to conventional LC systems. The performance of Kinetex C18 column (2.1 x 50 mm) and Acquity BEH C18 column (2.1 x 50 mm) for gradient separation of tetracyclines under acidic conditions (oxytetracycline, tetracycline, chlortetracycline, and doxycycline) and macrolides under alkaline conditions (tylosin, clarithromycin, roxithromycin, and carbomycin) was studied. The columns were compared by evaluation of their experimental peak capacity and its dependence on linear velocity and gradient slope. The maximal experimental peak capacities for analysis of tetracyclines were 51.8 (Acquity BEH C18 column) and 48.4 (Kinetex C18 column). This indicated that Kinetex C18 was a suitab
Název v anglickém jazyce
Comparison of LC Columns Packed with 2.6 mu m Core-Shell and Sub-2 mu m Porous Particles for Gradient Separation of Antibiotics
Popis výsledku anglicky
The recently introduced Kinetex C18 column packed with core-shell 2.6 mu m particles is declared to provide similar efficiency and short analysis as Acquity BEH C18 column with 1.7 mu m porous particles. Unlike Acquity BEH C18 column, Kinetex C18 columnexhibited lower column backpressure making this column compatible to conventional LC systems. The performance of Kinetex C18 column (2.1 x 50 mm) and Acquity BEH C18 column (2.1 x 50 mm) for gradient separation of tetracyclines under acidic conditions (oxytetracycline, tetracycline, chlortetracycline, and doxycycline) and macrolides under alkaline conditions (tylosin, clarithromycin, roxithromycin, and carbomycin) was studied. The columns were compared by evaluation of their experimental peak capacity and its dependence on linear velocity and gradient slope. The maximal experimental peak capacities for analysis of tetracyclines were 51.8 (Acquity BEH C18 column) and 48.4 (Kinetex C18 column). This indicated that Kinetex C18 was a suitab
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
EE - Mikrobiologie, virologie
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/1M06011" target="_blank" >1M06011: Centrum molekulárních metod monitorování difúzního znečištění životního prostředí</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>Z - Vyzkumny zamer (s odkazem do CEZ)<br>S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2011
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Chromatographia
ISSN
0009-5893
e-ISSN
—
Svazek periodika
74
Číslo periodika v rámci svazku
1
Stát vydavatele periodika
NL - Nizozemsko
Počet stran výsledku
9
Strana od-do
19-27
Kód UT WoS článku
000291745400003
EID výsledku v databázi Scopus
—