In Vivo Determination of Organellar pH Using a Universal Wavelength-Based Confocal Microscopy Approach
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216208%3A11310%2F12%3A10118891" target="_blank" >RIV/00216208:11310/12:10118891 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/61388971:_____/12:00377982
Výsledek na webu
<a href="http://www.plosone.org/article/info%3Adoi%2F10.1371%2Fjournal.pone.0033229" target="_blank" >http://www.plosone.org/article/info%3Adoi%2F10.1371%2Fjournal.pone.0033229</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1371/journal.pone.0033229" target="_blank" >10.1371/journal.pone.0033229</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
In Vivo Determination of Organellar pH Using a Universal Wavelength-Based Confocal Microscopy Approach
Popis výsledku v původním jazyce
Many essential cellular processes are affected by transmembrane H+ gradients and intracellular pH (pHi). The research of such metabolic events calls for a non-invasive method to monitor pHi within individual subcellular compartments. We present a novel confocal microscopy approach for the determination of organellar pHi in living cells expressing pH-dependent ratiometric fluorescent proteins. Unlike conventional intensity-based fluorometry, our method relies on emission wavelength scans at single-organelle resolution to produce wavelength-based pH estimates both accurate and robust to low-signal artifacts. Analyses of Ato1p-pHluorin and Ato1p-mCherry yeast cells revealed previously unreported wavelength shifts in pHluorin emission which, together withratiometric mCherry, allowed for high-precision quantification of actual physiological pH values and evidenced dynamic pHi changes throughout the different stages of yeast colony development. Additionally, comparative pH quantification of
Název v anglickém jazyce
In Vivo Determination of Organellar pH Using a Universal Wavelength-Based Confocal Microscopy Approach
Popis výsledku anglicky
Many essential cellular processes are affected by transmembrane H+ gradients and intracellular pH (pHi). The research of such metabolic events calls for a non-invasive method to monitor pHi within individual subcellular compartments. We present a novel confocal microscopy approach for the determination of organellar pHi in living cells expressing pH-dependent ratiometric fluorescent proteins. Unlike conventional intensity-based fluorometry, our method relies on emission wavelength scans at single-organelle resolution to produce wavelength-based pH estimates both accurate and robust to low-signal artifacts. Analyses of Ato1p-pHluorin and Ato1p-mCherry yeast cells revealed previously unreported wavelength shifts in pHluorin emission which, together withratiometric mCherry, allowed for high-precision quantification of actual physiological pH values and evidenced dynamic pHi changes throughout the different stages of yeast colony development. Additionally, comparative pH quantification of
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
EB - Genetika a molekulární biologie
OECD FORD obor
—
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>Z - Vyzkumny zamer (s odkazem do CEZ)<br>I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2012
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
PLoS ONE
ISSN
1932-6203
e-ISSN
—
Svazek periodika
7
Číslo periodika v rámci svazku
3
Stát vydavatele periodika
US - Spojené státy americké
Počet stran výsledku
12
Strana od-do
—
Kód UT WoS článku
000303857100023
EID výsledku v databázi Scopus
—