A planar, solid-state amperometric sensor for nitrogen dioxide, employing an ionic liquid electrolyte contained in a polymeric matrix
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216208%3A11310%2F12%3A10123666" target="_blank" >RIV/00216208:11310/12:10123666 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/61388980:_____/12:00387942
Výsledek na webu
<a href="http://dx.doi.org/10.1016/j.snb.2011.11.037" target="_blank" >http://dx.doi.org/10.1016/j.snb.2011.11.037</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.snb.2011.11.037" target="_blank" >10.1016/j.snb.2011.11.037</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
A planar, solid-state amperometric sensor for nitrogen dioxide, employing an ionic liquid electrolyte contained in a polymeric matrix
Popis výsledku v původním jazyce
A new type of electrolyte, based on immobilization of a hydrophobic ionic liquid, 1-butyl-3-methylimidazolium hexafluorophosphate (BMIPF6) or 1-ethyl-3-methylimidazolium bis(trifluoromethyl-sulfonyl)-imide (EMITESI) within the structure of partially cross-linked poly(ethylene glycol) methyl ether rnethacrylate (PEGMEMA), was tested for use in planar, solid state amperometric sensors, using nitrogen dioxide as the test analyte. Nitrogen dioxide contained in the air was reduced on a gold minigrid indicator electrode at a potential of -900 mV vs. a Pt/air pseudoreference electrode. The effects of the electrolyte composition, the indicator electrode surface area and the test gas relative humidity on the sensor response were studied. The principal analytical parameters obtained in this study were compared with those published for NO2 sensors containing other polymeric electrolytes and other indicator electrodes. There is no substantial difference in these parameters. however, the present se
Název v anglickém jazyce
A planar, solid-state amperometric sensor for nitrogen dioxide, employing an ionic liquid electrolyte contained in a polymeric matrix
Popis výsledku anglicky
A new type of electrolyte, based on immobilization of a hydrophobic ionic liquid, 1-butyl-3-methylimidazolium hexafluorophosphate (BMIPF6) or 1-ethyl-3-methylimidazolium bis(trifluoromethyl-sulfonyl)-imide (EMITESI) within the structure of partially cross-linked poly(ethylene glycol) methyl ether rnethacrylate (PEGMEMA), was tested for use in planar, solid state amperometric sensors, using nitrogen dioxide as the test analyte. Nitrogen dioxide contained in the air was reduced on a gold minigrid indicator electrode at a potential of -900 mV vs. a Pt/air pseudoreference electrode. The effects of the electrolyte composition, the indicator electrode surface area and the test gas relative humidity on the sensor response were studied. The principal analytical parameters obtained in this study were compared with those published for NO2 sensors containing other polymeric electrolytes and other indicator electrodes. There is no substantial difference in these parameters. however, the present se
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
CG - Elektrochemie
OECD FORD obor
—
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)<br>I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2012
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Sensors and Actuators, B: Chemical
ISSN
0925-4005
e-ISSN
—
Svazek periodika
161
Číslo periodika v rámci svazku
1
Stát vydavatele periodika
NL - Nizozemsko
Počet stran výsledku
7
Strana od-do
811-817
Kód UT WoS článku
000301549400110
EID výsledku v databázi Scopus
—