Determination of 4-Aminobiphenyl and 4-Nitrobiphenyl by HPLC with Electrochemical, UV Spectrophotometric, and Fluorescent Detection
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216208%3A11310%2F13%3A10134225" target="_blank" >RIV/00216208:11310/13:10134225 - isvavai.cz</a>
Výsledek na webu
<a href="http://www.electrochemsci.org/papers/vol8/80202524.pdf" target="_blank" >http://www.electrochemsci.org/papers/vol8/80202524.pdf</a>
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Determination of 4-Aminobiphenyl and 4-Nitrobiphenyl by HPLC with Electrochemical, UV Spectrophotometric, and Fluorescent Detection
Popis výsledku v původním jazyce
HPLC systems with electrochemical, UV spectrophotometric, and fluorescent detectors were used to determine genotoxic derivatives of biphenyl -4-aminobiphenyl (4-ABP) and 4-nitrobiphenyl (4-NBP). As 4-NBP cannot be determined by electrochemical and fluorescent detector directly, reduction of 4-NBP to 4-ABP (making use of a titanium(III)-based reducing agent) was investigated and optimized. UV detection was found to be the least sensitive and fluorescent detection the most sensitive one. Limits of detection (LDs) for 4-ABP in the presence of a reducing agent were 6.0 x 10(-6) mol L-1, 2.0 x 10(-6) mol L-1, and 8.0 x 10(-8) mol L-1 for UV, electrochemical, and fluorescent detection, respectively. For the determination of 4-NBP after its reduction to 4-ABP, the obtained LDs were 8.0 x 10(-6) mol L-1 (UV), 4.0 x 10(-6) mol L-1 (electrochemical), and 2.0 x 10(-7) mol L-1 (fluorescent detection). Moreover, it was also possible to determine 4-NBP directly using HPLC with UV detection, where th
Název v anglickém jazyce
Determination of 4-Aminobiphenyl and 4-Nitrobiphenyl by HPLC with Electrochemical, UV Spectrophotometric, and Fluorescent Detection
Popis výsledku anglicky
HPLC systems with electrochemical, UV spectrophotometric, and fluorescent detectors were used to determine genotoxic derivatives of biphenyl -4-aminobiphenyl (4-ABP) and 4-nitrobiphenyl (4-NBP). As 4-NBP cannot be determined by electrochemical and fluorescent detector directly, reduction of 4-NBP to 4-ABP (making use of a titanium(III)-based reducing agent) was investigated and optimized. UV detection was found to be the least sensitive and fluorescent detection the most sensitive one. Limits of detection (LDs) for 4-ABP in the presence of a reducing agent were 6.0 x 10(-6) mol L-1, 2.0 x 10(-6) mol L-1, and 8.0 x 10(-8) mol L-1 for UV, electrochemical, and fluorescent detection, respectively. For the determination of 4-NBP after its reduction to 4-ABP, the obtained LDs were 8.0 x 10(-6) mol L-1 (UV), 4.0 x 10(-6) mol L-1 (electrochemical), and 2.0 x 10(-7) mol L-1 (fluorescent detection). Moreover, it was also possible to determine 4-NBP directly using HPLC with UV detection, where th
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
CG - Elektrochemie
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/GBP206%2F12%2FG151" target="_blank" >GBP206/12/G151: Centrum nových přístupů k bioanalýze a molekulární diagnostice</a><br>
Návaznosti
S - Specificky vyzkum na vysokych skolach<br>I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2013
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
International Journal of Electrochemical Science
ISSN
1452-3981
e-ISSN
—
Svazek periodika
8
Číslo periodika v rámci svazku
2
Stát vydavatele periodika
RS - Srbská republika
Počet stran výsledku
12
Strana od-do
2524-2535
Kód UT WoS článku
000316565800084