Tubular and Microcylindrical Platinum Electrodes for Amperometric Detection of Aminobiphenyls and Aminonaphthalenes in HPLC
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216208%3A11310%2F14%3A10218638" target="_blank" >RIV/00216208:11310/14:10218638 - isvavai.cz</a>
Výsledek na webu
<a href="http://dx.doi.org/10.1002/elan.201300579" target="_blank" >http://dx.doi.org/10.1002/elan.201300579</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1002/elan.201300579" target="_blank" >10.1002/elan.201300579</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Tubular and Microcylindrical Platinum Electrodes for Amperometric Detection of Aminobiphenyls and Aminonaphthalenes in HPLC
Popis výsledku v původním jazyce
Platinum electrodes in microcylindrical and tubular arrangements were compared as working electrodes for amperometric detection of 2-aminobiphenyl, 4-aminobiphenyl, 1-aminonaphthalene, and 2-aminonaphthalene in HPLC. Factors influencing separation efficiency are favourable for microcylindrical arrangement while tubular arrangement exhibits higher sensitivities and lower limits of detection. These are in the range of 0.0078-0.027 mu molL(-1) for tubular, and 0.11-0.42 mu molL(-1) for microcylindrical arrangement. Further, a new method with nanomolar detection limits was proposed for determination of tested compounds in urine using solid phase extraction for preliminary separation and preconcentration of the analytes.
Název v anglickém jazyce
Tubular and Microcylindrical Platinum Electrodes for Amperometric Detection of Aminobiphenyls and Aminonaphthalenes in HPLC
Popis výsledku anglicky
Platinum electrodes in microcylindrical and tubular arrangements were compared as working electrodes for amperometric detection of 2-aminobiphenyl, 4-aminobiphenyl, 1-aminonaphthalene, and 2-aminonaphthalene in HPLC. Factors influencing separation efficiency are favourable for microcylindrical arrangement while tubular arrangement exhibits higher sensitivities and lower limits of detection. These are in the range of 0.0078-0.027 mu molL(-1) for tubular, and 0.11-0.42 mu molL(-1) for microcylindrical arrangement. Further, a new method with nanomolar detection limits was proposed for determination of tested compounds in urine using solid phase extraction for preliminary separation and preconcentration of the analytes.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
CG - Elektrochemie
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/GBP206%2F12%2FG151" target="_blank" >GBP206/12/G151: Centrum nových přístupů k bioanalýze a molekulární diagnostice</a><br>
Návaznosti
S - Specificky vyzkum na vysokych skolach<br>I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2014
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Electroanalysis
ISSN
1040-0397
e-ISSN
—
Svazek periodika
26
Číslo periodika v rámci svazku
4
Stát vydavatele periodika
DE - Spolková republika Německo
Počet stran výsledku
10
Strana od-do
687-696
Kód UT WoS článku
000333749500004
EID výsledku v databázi Scopus
—