Sample pretreatment for the capillary electrophoretic determination of organic acids in chromium(III) plating baths
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216208%3A11310%2F15%3A10318268" target="_blank" >RIV/00216208:11310/15:10318268 - isvavai.cz</a>
Výsledek na webu
<a href="http://dx.doi.org/10.1002/jssc.201500946" target="_blank" >http://dx.doi.org/10.1002/jssc.201500946</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1002/jssc.201500946" target="_blank" >10.1002/jssc.201500946</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Sample pretreatment for the capillary electrophoretic determination of organic acids in chromium(III) plating baths
Popis výsledku v původním jazyce
This work deals with the development and optimization of the sample pretreatment and consequent electrophoretic analysis of two modern plating baths containing chromium(III) and either citric acid or oxalic acid. Some model mixtures containing known amounts of components of industrial baths have been prepared to simulate simplified bath matrices. Prior to analysis, a sample pretreatment consisting of the addition of some agents that could release acid from the stable chromium complex was tested. Determination of organic anions was accomplished by indirect UV detection. The best results were achieved by precipitation of chromium(III) hydroxide. The content of oxalate and citrate in real samples was calculated as 96.5% (SD 2.3%) and 97.3% (SD 0.8%), respectively, of the declared amount. Very good robustness of the method and satisfactory repeatability of migration time and peak area were obtained. This simple inexpensive method is suitable for routine determination of citric and oxalic a
Název v anglickém jazyce
Sample pretreatment for the capillary electrophoretic determination of organic acids in chromium(III) plating baths
Popis výsledku anglicky
This work deals with the development and optimization of the sample pretreatment and consequent electrophoretic analysis of two modern plating baths containing chromium(III) and either citric acid or oxalic acid. Some model mixtures containing known amounts of components of industrial baths have been prepared to simulate simplified bath matrices. Prior to analysis, a sample pretreatment consisting of the addition of some agents that could release acid from the stable chromium complex was tested. Determination of organic anions was accomplished by indirect UV detection. The best results were achieved by precipitation of chromium(III) hydroxide. The content of oxalate and citrate in real samples was calculated as 96.5% (SD 2.3%) and 97.3% (SD 0.8%), respectively, of the declared amount. Very good robustness of the method and satisfactory repeatability of migration time and peak area were obtained. This simple inexpensive method is suitable for routine determination of citric and oxalic a
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
CB - Analytická chemie, separace
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/GA13-01440S" target="_blank" >GA13-01440S: Chirální supramolekulární polymery založené na derivatizovaných cyklodextrinech jako nové prostředí pro kapilární separační techniky</a><br>
Návaznosti
S - Specificky vyzkum na vysokych skolach<br>I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2015
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Journal of Separation Science
ISSN
1615-9306
e-ISSN
—
Svazek periodika
38
Číslo periodika v rámci svazku
24
Stát vydavatele periodika
DE - Spolková republika Německo
Počet stran výsledku
7
Strana od-do
4255-4261
Kód UT WoS článku
000367670300014
EID výsledku v databázi Scopus
2-s2.0-84955204234