Rapid determination of carbon isotope composition in carbonatites using isotope ratio mass spectrometry - Comparison of dual-inlet, elemental-analyzer and continuous-flow techniques
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216208%3A11310%2F19%3A10397575" target="_blank" >RIV/00216208:11310/19:10397575 - isvavai.cz</a>
Výsledek na webu
<a href="https://verso.is.cuni.cz/pub/verso.fpl?fname=obd_publikace_handle&handle=rhsh5Jjns9" target="_blank" >https://verso.is.cuni.cz/pub/verso.fpl?fname=obd_publikace_handle&handle=rhsh5Jjns9</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1002/rcm.8482" target="_blank" >10.1002/rcm.8482</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Rapid determination of carbon isotope composition in carbonatites using isotope ratio mass spectrometry - Comparison of dual-inlet, elemental-analyzer and continuous-flow techniques
Popis výsledku v původním jazyce
Rationale Applications where stable C and O isotope compositions are useful require routine instrumental techniques with a fast sample throughput which should also produce accurate and precise results. We present a comparison of three different instrumental isotope ratio mass spectrometry (IRMS) approaches (Dual Inlet - DI; Elemental Analyzer - EA; Continuous Flow - CF) to determine the stable isotope composition of carbon in carbonate matrices, with a focus on evaluating the optimum approach for less complex instrumental techniques. Methods The DI-IRMS method is taken as an absolute method for obtaining accurate and precise C-13/C-12 ratios with internal errors usually < +/- 0.01 parts per thousand (2SD) and long-term reproducibility better than +/- 0.03 parts per thousand (2SD). The drawbacks of DI-IRMS are that it requires extensive offline sample preparation, rather large sample sizes (commonly >20 mg) and extended analysis times. Results EA-IRMS provides rapidity of analysis, relatively non-complex technique optimization and large sample throughput sufficient to distinguish natural trends although the larger internal errors and poorer reproducibility must be considered. The major disadvantage of EA-IRMS lies in a constant offset of the C-13/C-12 ratios against DI-IRMS, large internal errors (+/- 0.2 parts per thousand, 2SD) and the worst reproducibility (+/- 0.3 parts per thousand, 2SD) of all the explored methods. The results acquired using CF-IRMS are comparable with those obtained by employing DI-IRMS with an external reproducibility better than +/- 0.2 parts per thousand (2SD). Compared with EA-IRMS, however, this technique requires more elaborate sample preparation - more akin to DI-IRMS. None of these two latter techniques can provide C isotope results for coexisting phases such as calcite, dolomite and ankerite unless they are physically separated and analyzed independently. Conclusions All methods are appropriate for C-13/C-12 determinations with CF-IRMS and EA-IRMS less applicable to high-precision measurements but relevant for studies requiring high sample throughput. Periodical analysis of matrix-matched reference materials during the analytical sequence is warranted for both EA-IRMS and CF-IRMS.
Název v anglickém jazyce
Rapid determination of carbon isotope composition in carbonatites using isotope ratio mass spectrometry - Comparison of dual-inlet, elemental-analyzer and continuous-flow techniques
Popis výsledku anglicky
Rationale Applications where stable C and O isotope compositions are useful require routine instrumental techniques with a fast sample throughput which should also produce accurate and precise results. We present a comparison of three different instrumental isotope ratio mass spectrometry (IRMS) approaches (Dual Inlet - DI; Elemental Analyzer - EA; Continuous Flow - CF) to determine the stable isotope composition of carbon in carbonate matrices, with a focus on evaluating the optimum approach for less complex instrumental techniques. Methods The DI-IRMS method is taken as an absolute method for obtaining accurate and precise C-13/C-12 ratios with internal errors usually < +/- 0.01 parts per thousand (2SD) and long-term reproducibility better than +/- 0.03 parts per thousand (2SD). The drawbacks of DI-IRMS are that it requires extensive offline sample preparation, rather large sample sizes (commonly >20 mg) and extended analysis times. Results EA-IRMS provides rapidity of analysis, relatively non-complex technique optimization and large sample throughput sufficient to distinguish natural trends although the larger internal errors and poorer reproducibility must be considered. The major disadvantage of EA-IRMS lies in a constant offset of the C-13/C-12 ratios against DI-IRMS, large internal errors (+/- 0.2 parts per thousand, 2SD) and the worst reproducibility (+/- 0.3 parts per thousand, 2SD) of all the explored methods. The results acquired using CF-IRMS are comparable with those obtained by employing DI-IRMS with an external reproducibility better than +/- 0.2 parts per thousand (2SD). Compared with EA-IRMS, however, this technique requires more elaborate sample preparation - more akin to DI-IRMS. None of these two latter techniques can provide C isotope results for coexisting phases such as calcite, dolomite and ankerite unless they are physically separated and analyzed independently. Conclusions All methods are appropriate for C-13/C-12 determinations with CF-IRMS and EA-IRMS less applicable to high-precision measurements but relevant for studies requiring high sample throughput. Periodical analysis of matrix-matched reference materials during the analytical sequence is warranted for both EA-IRMS and CF-IRMS.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
10505 - Geology
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2019
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Rapid Communications in Mass Spectrometry
ISSN
0951-4198
e-ISSN
—
Svazek periodika
33
Číslo periodika v rámci svazku
16
Stát vydavatele periodika
GB - Spojené království Velké Británie a Severního Irska
Počet stran výsledku
8
Strana od-do
1355-1362
Kód UT WoS článku
000476751300008
EID výsledku v databázi Scopus
2-s2.0-85069756862