Continuous monitoring of anthraquinone-based anticancer drugs by amperometric technique
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216208%3A11310%2F19%3A10409586" target="_blank" >RIV/00216208:11310/19:10409586 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/26234386:_____/20:N0000007 RIV/61388955:_____/19:00568216
Výsledek na webu
<a href="http://web.natur.cuni.cz/analchem/isc/isc15.pdf" target="_blank" >http://web.natur.cuni.cz/analchem/isc/isc15.pdf</a>
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Continuous monitoring of anthraquinone-based anticancer drugs by amperometric technique
Popis výsledku v původním jazyce
This contribution is focused on the development of electroanalytical methods for the monitoring of anthraquinone-based anticancer drugs in physiological solution by combination of liquid-flow system and dialysis catheter, possibly inserted into blood circulation of patients. For this purpose, amperometric detection with dual glassy carbon electrode was developed and derivate of these drugs, anthraquinone-2-sulphonate, was used as a model compound. Two different flow rates of carrier solution (physiological solution) were tested (specifically, 1 and 5 μL min-1) and the dependence of peak currents of anthraquinone-2-sulphonate on its concentration was verified.
Název v anglickém jazyce
Continuous monitoring of anthraquinone-based anticancer drugs by amperometric technique
Popis výsledku anglicky
This contribution is focused on the development of electroanalytical methods for the monitoring of anthraquinone-based anticancer drugs in physiological solution by combination of liquid-flow system and dialysis catheter, possibly inserted into blood circulation of patients. For this purpose, amperometric detection with dual glassy carbon electrode was developed and derivate of these drugs, anthraquinone-2-sulphonate, was used as a model compound. Two different flow rates of carrier solution (physiological solution) were tested (specifically, 1 and 5 μL min-1) and the dependence of peak currents of anthraquinone-2-sulphonate on its concentration was verified.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
10406 - Analytical chemistry
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2019
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Proceedings of the 15th International Students Conference "Modern Analytical Chemistry"
ISBN
978-80-7444-068-7
ISSN
—
e-ISSN
—
Počet stran výsledku
4
Strana od-do
238-241
Název nakladatele
Univerzita Karlova, Přírodovědecká fakulta
Místo vydání
Praha
Místo konání akce
Prague
Datum konání akce
19. 9. 2019
Typ akce podle státní příslušnosti
EUR - Evropská akce
Kód UT WoS článku
000576787700039