Effect of metal sensitizers on photochemical vapor generation of bismuth for analytical atomic spectrometry
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216208%3A11310%2F19%3A10409592" target="_blank" >RIV/00216208:11310/19:10409592 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/68081715:_____/19:00508762
Výsledek na webu
<a href="http://web.natur.cuni.cz/analchem/isc/isc15.pdf" target="_blank" >http://web.natur.cuni.cz/analchem/isc/isc15.pdf</a>
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Effect of metal sensitizers on photochemical vapor generation of bismuth for analytical atomic spectrometry
Popis výsledku v původním jazyce
Conditions of photochemical vapor generation of bismuth were optimized in a flow-injection system with a standard mercury low-pressure tube lamp and a coiled reactor. A high-resolution continuum source atomic absorption spectrometer was used as a detector that was equipped with a miniature diffusion flame as an atomizer. The influence of flow rate of a carrier gas, irradiation time and composition of a reaction medium was investigated. Combination of 40% (v/v) acetic acid with 1.25% (v/v) formic acid was found optimal. Subsequently, the use of various metals as sensitizers was studied to achieve maximum generation efficiency. Except the already published positive effect of Fe2+, three new sensitizers were found, with the enhancement effect in the following order: Cu2+ < Cd2+ << Co2+. Interference from nitric acid which is commonly used for digestion of real samples was investigated. The limit of detection achieved with the optimal conditions was 5.9 μg L-1.
Název v anglickém jazyce
Effect of metal sensitizers on photochemical vapor generation of bismuth for analytical atomic spectrometry
Popis výsledku anglicky
Conditions of photochemical vapor generation of bismuth were optimized in a flow-injection system with a standard mercury low-pressure tube lamp and a coiled reactor. A high-resolution continuum source atomic absorption spectrometer was used as a detector that was equipped with a miniature diffusion flame as an atomizer. The influence of flow rate of a carrier gas, irradiation time and composition of a reaction medium was investigated. Combination of 40% (v/v) acetic acid with 1.25% (v/v) formic acid was found optimal. Subsequently, the use of various metals as sensitizers was studied to achieve maximum generation efficiency. Except the already published positive effect of Fe2+, three new sensitizers were found, with the enhancement effect in the following order: Cu2+ < Cd2+ << Co2+. Interference from nitric acid which is commonly used for digestion of real samples was investigated. The limit of detection achieved with the optimal conditions was 5.9 μg L-1.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
10406 - Analytical chemistry
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach<br>I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2019
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Proceedings of the 15th International Students Conference "Modern Analytical Chemistry"
ISBN
978-80-7444-068-7
ISSN
—
e-ISSN
—
Počet stran výsledku
6
Strana od-do
257-262
Název nakladatele
Univerzita Karlova, Přírodovědecká fakulta
Místo vydání
Praha
Místo konání akce
Prague
Datum konání akce
19. 9. 2019
Typ akce podle státní příslušnosti
EUR - Evropská akce
Kód UT WoS článku
000576787700042