The use of non-traditional carbon film electrode based on microcrystalline natural graphite - polystyrene composite film for amperometric determination of 5-aminoquinoline using flow injection analysis minimising electrode fouling
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216208%3A11310%2F21%3A10429958" target="_blank" >RIV/00216208:11310/21:10429958 - isvavai.cz</a>
Výsledek na webu
<a href="https://verso.is.cuni.cz/pub/verso.fpl?fname=obd_publikace_handle&handle=FcbY3YgtGv" target="_blank" >https://verso.is.cuni.cz/pub/verso.fpl?fname=obd_publikace_handle&handle=FcbY3YgtGv</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.jelechem.2021.115085" target="_blank" >10.1016/j.jelechem.2021.115085</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
The use of non-traditional carbon film electrode based on microcrystalline natural graphite - polystyrene composite film for amperometric determination of 5-aminoquinoline using flow injection analysis minimising electrode fouling
Popis výsledku v původním jazyce
Flow injection analysis (FIA) with amperometric detection (AD) at a novel type of carbon film electrode (CFE) based on microcrystalline natural graphite ? polystyrene composite film was used for fast and sensitive determination of genotoxic 5-aminoquinoline. CFE is a recently developed electrode with large potential window, good sensitivity, and easily renewable surface. Under optimized conditions, limit of quantitation (LOQ) of 1?10?6 mol L?1 and RSD of 2.48% was achieved and problems with working electrode passivation were successfully minimised.
Název v anglickém jazyce
The use of non-traditional carbon film electrode based on microcrystalline natural graphite - polystyrene composite film for amperometric determination of 5-aminoquinoline using flow injection analysis minimising electrode fouling
Popis výsledku anglicky
Flow injection analysis (FIA) with amperometric detection (AD) at a novel type of carbon film electrode (CFE) based on microcrystalline natural graphite ? polystyrene composite film was used for fast and sensitive determination of genotoxic 5-aminoquinoline. CFE is a recently developed electrode with large potential window, good sensitivity, and easily renewable surface. Under optimized conditions, limit of quantitation (LOQ) of 1?10?6 mol L?1 and RSD of 2.48% was achieved and problems with working electrode passivation were successfully minimised.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
10406 - Analytical chemistry
Návaznosti výsledku
Projekt
<a href="/cs/project/GC20-01417J" target="_blank" >GC20-01417J: Nové přístupy zabraňující pasivaci elektrod při monitorování environmentálních organických polutantů</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2021
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Journal of Electroanalytical Chemistry
ISSN
1572-6657
e-ISSN
—
Svazek periodika
885
Číslo periodika v rámci svazku
March
Stát vydavatele periodika
CH - Švýcarská konfederace
Počet stran výsledku
5
Strana od-do
115085
Kód UT WoS článku
000636226600006
EID výsledku v databázi Scopus
2-s2.0-85102977864