Design of the testing procedure for investigation of Eryx conicus dermal armour characteristics
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216208%3A11310%2F24%3A10489897" target="_blank" >RIV/00216208:11310/24:10489897 - isvavai.cz</a>
Výsledek na webu
<a href="https://doi.org/10.14311/APP.2024.48.0061" target="_blank" >https://doi.org/10.14311/APP.2024.48.0061</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.14311/APP.2024.48.0061" target="_blank" >10.14311/APP.2024.48.0061</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Design of the testing procedure for investigation of Eryx conicus dermal armour characteristics
Popis výsledku v původním jazyce
The aim of this work is to develop an experimental method suitable for the mechanical testing of highly non-standard biological samples such as snake skin with osteoderms. The objective of the method is to determine, whether the osteoderms provide a protective function for the animal in its natural environment. For this purpose, a simulation of rodents biting the skin based on uni-axial compressive loading using a synthetic tooth as a penetrator was developed with an emphasis on integration with X-ray scanners to facilitate in-situ testing. To identify and characterise the structure of snake skin and to prove the protective function of osteoderms, all samples were subjected to high resolution X-ray computed tomography. The results of the experiments are presented in the form of stress-strain curves and a map of the tangent modulus.
Název v anglickém jazyce
Design of the testing procedure for investigation of Eryx conicus dermal armour characteristics
Popis výsledku anglicky
The aim of this work is to develop an experimental method suitable for the mechanical testing of highly non-standard biological samples such as snake skin with osteoderms. The objective of the method is to determine, whether the osteoderms provide a protective function for the animal in its natural environment. For this purpose, a simulation of rodents biting the skin based on uni-axial compressive loading using a synthetic tooth as a penetrator was developed with an emphasis on integration with X-ray scanners to facilitate in-situ testing. To identify and characterise the structure of snake skin and to prove the protective function of osteoderms, all samples were subjected to high resolution X-ray computed tomography. The results of the experiments are presented in the form of stress-strain curves and a map of the tangent modulus.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
10613 - Zoology
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2024
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Acta Polytechnica
ISBN
978-80-01-07358-2
ISSN
1210-2709
e-ISSN
1805-2363
Počet stran výsledku
5
Strana od-do
61-65
Název nakladatele
Czech Technical University in Prague
Místo vydání
Praha
Místo konání akce
Rome
Datum konání akce
5. 6. 2024
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—