Detailed analysis of POD method applied on turbulent flow
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216208%3A11320%2F12%3A10132835" target="_blank" >RIV/00216208:11320/12:10132835 - isvavai.cz</a>
Výsledek na webu
<a href="http://www.epj-conferences.org/index.php?option=com_article&access=doi&doi=10.1051/epjconf/20122501038&Itemid=129" target="_blank" >http://www.epj-conferences.org/index.php?option=com_article&access=doi&doi=10.1051/epjconf/20122501038&Itemid=129</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1051/epjconf/20122501038" target="_blank" >10.1051/epjconf/20122501038</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Detailed analysis of POD method applied on turbulent flow
Popis výsledku v původním jazyce
Proper orthogonal decomposition (POD) of a very turbulent flow inside a street canyon is performed. The energy contribution of each mode is obtained. Also, physical meaning of the POD result is clarified. Particular modes of POD are assigned to the particular flow events like a sweep event, a vortex behind a roof or a vortex at the bottom of a street. Test of POD sensitivity to the acquisition time of data records is done. Test with decreasing sample frequency is also executed. Further, interpolation ofPOD expansion coefficient is performed in order to test possible increase in sample frequency and get new information about the flow from the POD analysis. We tested a linear and a spline type of the interpolation and the linear one carried out a slightly better result.
Název v anglickém jazyce
Detailed analysis of POD method applied on turbulent flow
Popis výsledku anglicky
Proper orthogonal decomposition (POD) of a very turbulent flow inside a street canyon is performed. The energy contribution of each mode is obtained. Also, physical meaning of the POD result is clarified. Particular modes of POD are assigned to the particular flow events like a sweep event, a vortex behind a roof or a vortex at the bottom of a street. Test of POD sensitivity to the acquisition time of data records is done. Test with decreasing sample frequency is also executed. Further, interpolation ofPOD expansion coefficient is performed in order to test possible increase in sample frequency and get new information about the flow from the POD analysis. We tested a linear and a spline type of the interpolation and the linear one carried out a slightly better result.
Klasifikace
Druh
O - Ostatní výsledky
CEP obor
BK - Mechanika tekutin
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2012
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů