Electrochemical Pretreatment of Carbon Fiber Microelectrodes Based on Sinusoidal-wave Potential Cycling and its Application to Amperometric Sensing of Bioactive Compounds
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216208%3A11320%2F13%3A10144246" target="_blank" >RIV/00216208:11320/13:10144246 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/61989592:15310/13:33145919 RIV/61989592:15110/13:33145919
Výsledek na webu
<a href="http://www.ingentaconnect.com/content/ben/cac/2013/00000009/00000002/art00015" target="_blank" >http://www.ingentaconnect.com/content/ben/cac/2013/00000009/00000002/art00015</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.2174/157341113805219018" target="_blank" >10.2174/157341113805219018</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Electrochemical Pretreatment of Carbon Fiber Microelectrodes Based on Sinusoidal-wave Potential Cycling and its Application to Amperometric Sensing of Bioactive Compounds
Popis výsledku v původním jazyce
We demonstrate the electrochemical pretreatment of carbon fiber microelectrodes (CFEs) based on the sinusoidal-wave potential cycling (50 Hz) of CFEs prior to amperometric analysis. The surface modification and morphology of CFEs after pretreatment was studied using Raman spectroscopy and scanning electron microscopy. The pretreated CFEs were extensively tested for sensing of bioactive compounds (dopamine, nitric oxide, ascorbate and nitrite) by constant current amperometry at 830 mV vs. Ag/AgCl.
Název v anglickém jazyce
Electrochemical Pretreatment of Carbon Fiber Microelectrodes Based on Sinusoidal-wave Potential Cycling and its Application to Amperometric Sensing of Bioactive Compounds
Popis výsledku anglicky
We demonstrate the electrochemical pretreatment of carbon fiber microelectrodes (CFEs) based on the sinusoidal-wave potential cycling (50 Hz) of CFEs prior to amperometric analysis. The surface modification and morphology of CFEs after pretreatment was studied using Raman spectroscopy and scanning electron microscopy. The pretreated CFEs were extensively tested for sensing of bioactive compounds (dopamine, nitric oxide, ascorbate and nitrite) by constant current amperometry at 830 mV vs. Ag/AgCl.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
CG - Elektrochemie
OECD FORD obor
—
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2013
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Current Analytical Chemistry
ISSN
1573-4110
e-ISSN
—
Svazek periodika
9
Číslo periodika v rámci svazku
2
Stát vydavatele periodika
AE - Spojené arabské emiráty
Počet stran výsledku
7
Strana od-do
305-311
Kód UT WoS článku
000324491800014