The Belle II Silicon Vertex Detector
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216208%3A11320%2F13%3A10193488" target="_blank" >RIV/00216208:11320/13:10193488 - isvavai.cz</a>
Výsledek na webu
<a href="http://dx.doi.org/10.1016/j.nima.2013.05.171" target="_blank" >http://dx.doi.org/10.1016/j.nima.2013.05.171</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.nima.2013.05.171" target="_blank" >10.1016/j.nima.2013.05.171</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
The Belle II Silicon Vertex Detector
Popis výsledku v původním jazyce
The KEKB machine and the Belle experiment in Tsukuba (japan) are now undergoing an upgrade, leading to an ultimate luminosity of 8 x 1035 cm(-2) s(-1) in order to measure rare decays in the B system with high statistics. The previous vertex detector cannot cope with this 40-fold increase of luminosity and thus needs to be replaced. Belle II will be equipped with a two-layer Pixel Detector surrounding the beam pipe, and four layers of double-sided silicon strip sensors at higher radii than the old detector. The Silicon Vertex Detector (SVD) will have a total sensitive area of 1.13 m(2) and 223,744 channels twice as many as its predecessor. All silicon sensors will be made from 150 mm wafers in order to maximize their size and thus to reduce the relativecontribution of the support structure. The forward part has slanted sensors of trapezoidal shape to improve the measurement precision and to minimize the amount of material as seen by particles from the vertex. Fast-shaping front-end amp
Název v anglickém jazyce
The Belle II Silicon Vertex Detector
Popis výsledku anglicky
The KEKB machine and the Belle experiment in Tsukuba (japan) are now undergoing an upgrade, leading to an ultimate luminosity of 8 x 1035 cm(-2) s(-1) in order to measure rare decays in the B system with high statistics. The previous vertex detector cannot cope with this 40-fold increase of luminosity and thus needs to be replaced. Belle II will be equipped with a two-layer Pixel Detector surrounding the beam pipe, and four layers of double-sided silicon strip sensors at higher radii than the old detector. The Silicon Vertex Detector (SVD) will have a total sensitive area of 1.13 m(2) and 223,744 channels twice as many as its predecessor. All silicon sensors will be made from 150 mm wafers in order to maximize their size and thus to reduce the relativecontribution of the support structure. The forward part has slanted sensors of trapezoidal shape to improve the measurement precision and to minimize the amount of material as seen by particles from the vertex. Fast-shaping front-end amp
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
BF - Elementární částice a fyzika vysokých energií
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/LA10033" target="_blank" >LA10033: Účast v experimentu Belle a Belle II: studium rozpadů B-mezonů</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2013
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
ISSN
0168-9002
e-ISSN
—
Svazek periodika
732
Číslo periodika v rámci svazku
1
Stát vydavatele periodika
NL - Nizozemsko
Počet stran výsledku
4
Strana od-do
83-86
Kód UT WoS článku
000327490400018
EID výsledku v databázi Scopus
—