A survey of the principles for primary standards for atmospheric halogenated-hydrocarbon-leaks
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216208%3A11320%2F15%3A10319577" target="_blank" >RIV/00216208:11320/15:10319577 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/00177016:_____/15:#0000921
Výsledek na webu
<a href="http://dx.doi.org/10.1088/0026-1394/52/4/R11" target="_blank" >http://dx.doi.org/10.1088/0026-1394/52/4/R11</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1088/0026-1394/52/4/R11" target="_blank" >10.1088/0026-1394/52/4/R11</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
A survey of the principles for primary standards for atmospheric halogenated-hydrocarbon-leaks
Popis výsledku v původním jazyce
Albeit the utilization of halogenated hydrocarbons in new devices is suppressed gradually, due to the protection of environment, large amounts of them still remain in existing equipment. It is important for metrology to carry out proper leak measurements of these devices during their service life with traceability to high quality primary standards. Efficient methods have been developed for vacuum leaks (gas outflow into vacuum) but halogenated hydrocarbons leak out into the atmosphere under real conditions. The design of primary standards that meet this condition is considerably more difficult and they are still rather rare. This paper gives an insight into the principles used for these standards, which can be classified into two groups: methods sensitive to the gas species and methods insensitive to the gas species.
Název v anglickém jazyce
A survey of the principles for primary standards for atmospheric halogenated-hydrocarbon-leaks
Popis výsledku anglicky
Albeit the utilization of halogenated hydrocarbons in new devices is suppressed gradually, due to the protection of environment, large amounts of them still remain in existing equipment. It is important for metrology to carry out proper leak measurements of these devices during their service life with traceability to high quality primary standards. Efficient methods have been developed for vacuum leaks (gas outflow into vacuum) but halogenated hydrocarbons leak out into the atmosphere under real conditions. The design of primary standards that meet this condition is considerably more difficult and they are still rather rare. This paper gives an insight into the principles used for these standards, which can be classified into two groups: methods sensitive to the gas species and methods insensitive to the gas species.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
JB - Senzory, čidla, měření a regulace
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2015
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Metrologia
ISSN
0026-1394
e-ISSN
—
Svazek periodika
52
Číslo periodika v rámci svazku
4
Stát vydavatele periodika
FR - Francouzská republika
Počet stran výsledku
11
Strana od-do
"R11"-"R21"
Kód UT WoS článku
000358934800004
EID výsledku v databázi Scopus
2-s2.0-84938703913